Atec Agilent-E8257D User Manual
Page 15
15
Modulation types
AM, FM, and
FM
Input impedance
50 or 600
(nom) switched
High/low indicator
(100 Hz to 10 MHz BW,
Activated when input level error exceeds 3% (nom)
ac coupled inputs only)
Dual function generators provides two independent signals (internal1 and internal2) for
use with AM, FM,
FM, or LF Out.
Waveforms
Sine, square, positive ramp, negative ramp, triangle,
Gaussian noise, uniform noise, swept sine, dual sine
1
Rate range
Sine
0.5 Hz to 1 MHz
Square, ramp, triangle
0.5 Hz to 100 kHz
Resolution
0.5 Hz
Accuracy
Same as timebase
LF Out
Output
Internal1 or internal2. Also provides monitoring of
internal1or internal2 when used for AM, FM, or
FM.
Amplitude
0 to 3 V
peak
, (nom) into 50 Ω
Output impedance
50 Ω (nom)
Swept sine mode: (frequency, phase continuous)
Operating modes
Triggered or continuous sweeps
Frequency range
1 Hz to 1 MHz
Sweep rate
0.5 Hz to 100 kHz sweeps/s, equivalent to sweep times
10 us to 2 s
Resolution
0.5 Hz (0.5 sweep/s)
External modulation inputs
(Ext1 & Ext2)
(Option UNT)
Internal modulation source
(Option UNT)
1. Internal2 is not available when using swept sine or dual sine modes.