Performance characteristics – Atec Agilent-2000-X Series User Manual
Page 19

19
Integrated Digital Voltmeter
Functions
ACrms, DC, DCrms, Frequency
Resolution
ACV/DCV: 3 digits Frequency: 5.5 digits
Measuring rate
100 times/ second
Autoranging
Automatic adjustment of vertical amplification to maximize the dynamic range of measurements.
Range meter
Graphical display of most recent measurement, plus extrema over the previous 3 seconds
.
Measurement range (specifications are typical)
Frequency Range
Vertical Range
Vertical Accuracy
ACRms
20 Hz - 100 KHz
100 MHz to 500 MHz: 1 mV/div to 5 V/
div** (1 MΩ and 50 Ohm)
1 GHz model: 1 mV/div to 5 V/div** (1
MΩ), 1mV/div to 1V/div (50 Ohm)
[DC vertical gain accuracy + 0.5% full scale
DCRms
20 Hz - 100 KHz
[DC vertical gain accuracy + DC vertical offset
accuracy + 0.25% full scale]
DC
NA
[DC vertical gain accuracy + DC vertical offset
accuracy + 0.25% full scale]
Frequency
counter
1Hz – BW of Scope
<10 mV/div: greater of 1 div or 5 mV; ≥
10 mV/div: 0.6 div
25 ppm ± 5 ppm per year (aging)
WaveGen – built-in function generator (specifications are typical)
(Continued)
Modulation
Modulation types: AM, FM, FSK
Carrier waveforms: sine, ramp
Modulation source: Internal (no external modulation capability)
AM:
Modulation waveform: sine, square, ramp
Modulation frequency (1Hz to 20 kHz)
Depth: 0% to 100%
FM:
Modulation: sine, square, ramp (1 Hz to 20 kHz)
Modulation frequency (1 Hz to 20 kHz)
Minimum carrier frequency: 10 kHz
Minimum deviation: 1 Hz
Maximum deviation: 100 kHz or (carrier frequency - 9 kHz), whichever is smaller.
FSK:
Modulation: 50% duty cycle square wave
FSK rate: 1 Hz to 20 kHz
Minimum carrier frequency: 10 kHz
Minimum hop frequency: 2 * FSK rate
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget