WaveGen – built-in function generator (specifications are typical)

Waveforms

Sine, square, pulse, triangle, ramp, noise, DC

Sine

• Frequency range: 0.1 Hz to 20 MHz
• Amplitude flatness: ±0.5 dB (relative to 1 kHz)
• Harmonic distortion: –40 dBc
• Spurious (non harmonics): –40 dBc
• Total harmonic distortion: 1%
• SNR (50 ohm load, 500 MHz BW) : 40 dB (Vpp ≥ 0.1 V); 30 dB (Vpp <0.1 V)

Square wave/pulse

• Frequency range: 0.1 Hz to 10 MHz
• Duty cycle: 20 to 80%
• Duty cycle resolution: Larger of 1% or 10 ns
• Pulse width: 20 ns minimum
• Pulse width resolution: 10 ns or 5 digits, whichever is larger
• Rise/fall time: 18 ns (10 to 90%)
• Overshoot: < 2%
• Asymmetry (at 50% DC): ±1% ± 5 ns
• Jitter (TIE RMS): 500 ps

Ramp/triangle wave

• Frequency range: 0.1 Hz to 100 kHz
• Linearity: 1%
• Variable symmetry: 0 to 100%
• Symmetry resolution: 1%

Noise

Bandwidth: 20 MHz typical

Frequency

• Sine wave and ramp accuracy:

◦ 130 ppm (frequency < 10 kHz)

◦ 50 ppm (frequency > 10 kHz)

• Square wave and pulse accuracy:

◦ [50+frequency/200] ppm (frequency < 25 kHz)

◦ 50 ppm (frequency ≥ 25 kHz)

• Resolution: 0.1 Hz or 4 digits, whichever is larger

Amplitude

• Range:

◦ 20 mVpp to 5 Vpp into Hi-Z

◦ 10 mVpp to 2.5 Vpp into 50 ohms

• Resolution: 100 µV or 3 digits, whichever is larger
• Accuracy: 2% (frequency = 1 kHz)

DC offset

• Range:

◦ ±2.5 V into Hi-Z

◦ ±1.25 V into 50 ohms

• Resolution: 100 μV or 3 digits, whichever is larger
• Accuracy: ±1.5% of offset setting ±1.5% of amplitude ±1 mV

Trigger output

Trigger output available on Trig out BNC