Atec Agilent-34980A User Manual
Page 9
9
Table 2. Multiplexer selection table—specifications and characteristics*
34921A
34922A
34923A
34924A
34925A
Channels/configurations
40 2-wire
70 2-wire
80 1-wire
70 2-wire
80 1-wire
20 4-wire
35 4-wire
40 2-wire
35 4-wire
40 2-wire
4-current
20 4-wire
20 4-wire
Switch type
Armature
Armature
Reed
Reed
Optically isolated FET
latching
latching
Input characteristics (per channel)
Max volts
± 300 V
[1]
± 300 V
[1]
± 150 V peak
[2]
± 150 V peak
[2]
± 80 V peak
[2]
Max current (DC, AC RMS)
Switch current
1 A
1 A
0.5 A
0.5 A
0.02 A
[8]
Carry current
2 A
2 A
1.5 A
1.5 A
Power (W, VA)
[6]
60 W
60 W
10 W
10 W
1.6 W
Volt-Hertz limit
10
8
10
8
10
8
10
8
10
7
General specifications
Offset voltage
[3]
< 3 uV
< 3 uV
< 50 uV
< 50 uV
< 3 uV
< 100 uV 1-wire
Initial closed channel res
[3]
< 1.5
Ω
< 1.5
Ω
< 1.5
Ω
[5]
< 1.5
Ω
[5]
< 700
Ω
Leakage current
[3]
N/A
N/A
N/A
N/A
20nA
[9]
T/C cold junction accuracy
[3, 10]
< 1°C
N/A
N/A
N/A
N/A
AC characteristics
Bandwidth at terminal block
[4]
45 MHz
25 MHz
45 MHz
25 MHz
1 MHz
10 MHz 1-wire
Crosstalk at terminal block (ch-ch)
[4]
300 kHz
-75 dB
-75 dB
-75 dB
-75 dB
N/A
1 MHz
-75 dB
-75 dB
-75 dB
-70 dB
20 MHz
-50 dB
-50 dB
-50 dB
-45 dB
45 MHz
-40 dB
-40 dB
Capacitance at terminal block
HI-LO
150 pF
250 pF
130 pF
200 pF
100pF
LO – earth
150 pF
200 pF
120 pF
170 pF
300pF (600pF 1-wire)
General characteristics
Relay life, typical
No load
100 M
100 M
1000 M
1000 M
N/A
10 V, 100 ma
10 M
10 M
10 M
10 M
N/A
Rated load
100 k
100 k
10 k
10 k
N/A
Scanning speeds
[7]
100 ch/sec
100 ch/sec
500 ch/sec
500 ch/sec
1000 ch/sec
Open/ close time, typical
4 ms/4 ms
4 ms/4 ms
0.5 ms/0.5 ms
0.5 ms/0.5 ms
0.25 ms/0.25 ms
Analog bus backplane connection
Yes
Yes
Yes
Yes
Yes
[1] DC or AC RMS voltage, channel-to-channel
or channel-to-earth
[2] Peak voltage, channel-to-channel or
channel-to-earth
[3] Into analog bus. System errors are included
in the internal DMM measurement accuracy
specifications
[4] 50
Ω source, 50 Ω load, differential
measurements verified with 4-port network
analyzer (Sdd21)
[5] With in-rush resistors bypassed
[6] Limited to 6 W of channel resistance power
loss per module
[7] Speeds are for 4-1/2 digits, delay 0, display
off, autozero off, and within bank
[8] DC or peak AC current
[9] Ambient temperature < 30°C
[10] Includes temperature reference and
temperature gradient from reference to
screw terminal block. Measured under worst
case heat loading of the mainframe. For
remote mount of terminal card accuracy
consult factory.