beautypg.com

Optical interfaces, Optical modules up to 155 mbit/s, Optical modules up to 622 mbit/s – Atec Acterna-JDSU-ANT-20SE User Manual

Page 9

background image

Optical Interfaces

All of the optical interfaces are intended for single-mode fibers. Acterna

offers a complete line of optical test adapters. Select one test adapter

each for the generator and receiver from the ordering information in

this data sheet. All optical interface options include the required

number of test adapters.

The STM-0 optical interface requires the option ªAdd SONETº.

Optical Modules up to 155 Mbit/s

Optical OC-1/3, STM-0/1, 1310 nm

BN 3060/91.01

Optical OC-1/3, STM-0/1, 1310 & 1550 nm BN 3060/91.02

Bit rate of TX and RX signal . . . . . . . . . . . . . . . . . . . . . . . 155 520 kbit/s

additionally, for STS-1/STM-0 mappings . . . . . . . . . . . 51 840 kbit/s

Line code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . scrambled NRZ

Generator unit

The generator meets the requirements of Telcordia GR-253,

ANSI T1.105.06 (ITU-T Rec. G.957, Tables 2 and 3).

Classes LR-1, LR-2, LR-3 (L1.1, L1.2 and L1.3) are covered.
There are two options for adapting to the required wavelength:

Wavelength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1310 nm,

1310 & 1550 nm (switchable in the instrument)

Output level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 dBm +2/±3 dB

with 1310 & 1550 nm option . . . . . . . . . . . . . . . . . 0 dBm +2/±3.5 dB

Receiver unit

The receiver unit meets the specifications of Telcordia GR-253,

ANSI T1.105.06 (ITU-T Rec. G.957) and fulfills classes IR-1, IR-2

(S1.1 and S1.2).
Wavelength range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1100 to 1580 nm

Input sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±8 to ±28 dBm

(±8 to ±34 dBm typ.)

Display of optical input level

Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 dB
155 Mbit/s electrical interface

for connecting the ANT-20SE to STM-1/STS-3 monitor points

Line code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . scrambled NRZ

Input voltage (peak-peak) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.2 to 1 V

Unbalanced input

Connector/impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SMA/50 O

Optical Modules up to 622 Mbit/s

Optical OC-1/3/12, STM-0/1/4, 1310 nm

BN 3060/91.11

Optical OC-1/3/12,

STM-0/1/4, 1310 & 1550 nm

BN 3060/91.12

Bit rate of TX and

RX signal. . . . . . . . . . . . . . . . . . . . . . . . . . 155 520 kbit/s, 622 080 kbit/s

additionally, for STS-1/STM-0 mappings . . . . . . . . . . . 51 840 kbit/s

Line code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . scrambled NRZ

Generator unit

The generator meets the requirements of Telcordia GR 253,

ANSI T1.105.06 (ITU-T Rec. G.957, Tables 2 and 3).

Classes LR-1, LR-2, LR-3 (L1.1, L1.2, L1.3, L4.1, L4.2 and L4.3) are

covered.

There are two options for adapting to the required wavelength:

Wavelength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1310 nm,

1310 & 1550 nm (switchable in the instrument)

Output level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 dBm +2/±3 dB

with 1310 & 1550 nm option . . . . . . . . . . . . . . . . . 0 dBm +2/±3.5 dB

Generation of OC-12 TX signal

In instruments with STS-1 mappings

The OC-12 TX signal consists of

± one internally generated STS-1 tributary signal with the other

11 tributaries filled with UNEQ or

± one internally generated STS-3c tributary signal with the other

three tributaries filled with UNEQ (with STS-3c mapping option

or ATM Basic Option BN 3060/90.50).

Generation of STM-4 TX signal

In instruments with STM-1 mappings

The STM-4 TX signal consists of

± four identical STM-1 tributary signals (AU-4), or

± one internally generated STM-1 tributary signal with the other

three tributaries filled with UNEQ.

Contents of the OC-12/STM-4 overhead bytes

For all bytes except B1, B2 and H1 to H3:

± The content of each byte is statically programmable or a user

defined byte-sequence p in m in n (p frames in m frames and the

entire sequence repeated n times) can be inserted.

For the E1, E2, F1 bytes and the DCC channels

D1 to D3 and D4 to D12:

± Transmission of a test pattern with bit error insertion (see main-

frame for pattern selection)

± Insertion of an external data signal (via the V.11 interface)
For the K1, K2, N1, N2 bytes:

± Insertion of the data signal via the V.11 interface
For the J0 bytes:

± Transmission of a 16-byte sequence, with CRC

Error insertion

Error types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B1 and B2 parity error

additionally, for OC-12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REI-L

for STM-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MS-REI

Triggering

Single errors or error ratio . . . . . . . . . . . . . . . . . . . 2610

±3

to 1610

±10

for B1 parity errors. . . . . . . . . . . . . . . . . . . . . . . . . . 2610

±4

to 1610

±10

Burst error: m anomalies in n periods

For FAS, B1, B2, B3, REI-L, REI-P . . . . . . . . . m= 1 to 4.86106 and

n= 2 to 8001 frames or 0.2 s to 600 s

Alarm generation, dynamic

Alarm types for OC-12 . . . . . . . . . . . . . . . . . . . . . . . LOF, AIS-L, RDI-L

for STM-4 . . . . . . . . . . . . . . . . . . . LOF, MS-AIS, MS-RDI

m alarms in n frames . . . . . . . . . . . . . . . . . . . m = 1 to n-1, n

max

= 8000

or

t1 alarm active, t2 alarm passive . . . . . . . . . . . . . . . . . . . . t1 = 0 to 60 s,

t2 = 0 to 600 s

Alarm generation, static (on/off)

Alarm types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LOS, LOF

additionally, for OC-12 . . . . . . . . . . . . . . . . . . . . . AIS-L, RDI-L, TIM-L

for STM-4 . . . . . . . . . . . . . . . . MS-AIS, MS-RDI, RS-TIM

Insertion on/off

9