beautypg.com

Atec Acterna-JDSU-ANT-20SE User Manual

Page 14

background image

This applies to all bit rates included in the mainframe configuration at

the appropriate electrical and optical interfaces.

Built-in modulation generator (sinewave) . . . . . . . . . 0.1 Hz to 5 MHz

External modulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 Hz to 5 MHz

Jitter amplitude . . . . . . . . . . . . . . . . . . . . as for jitter generator in UIpp

Jitter Analyzer

Measurement range

Peak-peak

Range I/Resolution . . . . . . . . . . . . . . . . . . . . 0 to 6.4 UIpp/1 mUIpp

Range II/Resolution . . . . . . . . . . . . . . . . . . . 0 to 80 UIpp/10 mUIpp

Range III/Resolution . . . . . . . . . . . . . . . . . 0 to 800 UIpp/100 mUIpp

RMS

Range I/Resolution . . . . . . . . . . . . . . . . . . . . 0 to 3.2 UIpp/1 mUIpp

Range II/Resolution . . . . . . . . . . . . . . . . . . . 0 to 40 UIpp/10 mUIpp

Range III/Resolution . . . . . . . . . . . . . . . . . 0 to 400 UIpp/100 mUIpp

Measurement accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . as per O.172

Demodulator output

75 O, BNC socket

Range I (0 to 6.4 UIpp) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.25 V/UIpp

Range II (0 to 80 UIpp) . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.025 V/UIpp

Range III (0 to 800 UIpp) . . . . . . . . . . . . . . . . . . . . . . . . 0.0025 V/UIpp

Wander Generator

Fully complies with or exceeds the requirements of ITU-T O.172

Bit rates

Wander generation at all implemented bit rates up to 622 Mbit/s

according to the equipment level of the instrument.

Amplitude range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to 200 000 UI

Frequency range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 mHz to 10 Hz

Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . as per O.172

Resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 mHz

Wander Analyzer

Fully complies with or exceeds the requirements of ITU-T O.172

Other sampling rates in addition to the 30/s rate are available for

detailed analysis versus time:

Sampling rate ± Low-pass filter ±

Test duration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/s - 0.1 Hz - 99 days

30/s - 10 Hz - 99 h

60/s - 20 Hz - 99 h

300/s - 100 Hz - 5000 s

Amplitude range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +1 ns to +10

6

s

Measurement accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . as per O.172

Reference signal input

Frequencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.544, 2.048, 5, 10 MHz

Bit rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.544, 2.048 Mbit/s

Balanced 110 O connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bantam

Clock input voltage

(sine or square wave) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 to 6.5 Vpp

HDB3/B8ZS input voltage . . . . . . . . . . . . . . . . . . . . . . . . .+3 V +10%

Coaxial 75 O connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .BNC

Clock input voltage

(sine or square wave) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 to 5 Vpp

HDB3/B8ZS input voltage . . . . . . . . . . . . . . . . . . . . . . +2.37 V +10%

Accessory: ªStandard Frequency Sourceº for wander applications, see

end of chapter

O.172 Jitter/Wander

up to 2488 Mbit/s

BN 3060/91.32

Jitter Generator

Fully complies with or exceeds the requirements of ITU-T O.172

Bit rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 488 320 kbit/s

Generator signal . . . . . . . . . . . . . . . . . . . test patterns, frame structures

depend on instrument configuration

Built-in modulation generator (sinewave)

or external . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1 Hz to 20 MHz

Jitter amplitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to 800 UI

Bit rate/

kHz

A1/

UIpp

A2/

UIpp

A3/

UIpp

A4/

UIpp

f0/

Hz

f1/

Hz

f2/

Hz

f3/

Hz

f4/

Hz

2 488 320

ANT-20SE

0.008

0.75

20

800

0.1

12.1

500

750 k

20 M

Modulator input

75 O, BNC socket

Modulation frequency . . . . . . . . . . . . . . . . . . . . . . . . 0.1 Hz to 20 MHz

Required sinusoidal voltage . . . . . . . . . . . . . . . . . . . . . . . . . 0 to 2 Vpp

Error limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . as per O.172

Jitter modulation of external signals in Through mode

In Through mode, jitter can be superimposed on an external 2488

Mbit/s signal in conjunction with the D&I option.

Internal and external modulation,

jitter amplitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . see jitter generator

Jitter Analyzer

Fully complies with or exceeds the requirements of ITU-T O.172

Bit rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 488 320 kbit/s

Measuring ranges

Range I/Resolution. . . . . . . . . . . . . . . . . . . . . . . . 0 to 2 UIpp/1 mUIpp

Range II/Resolution . . . . . . . . . . . . . . . . . . . . . 0 to 32 UIpp/10 mUIpp
RMS Range I/Resolution . . . . . . . . . . . . . . . . . . 0 to 1.0 UIpp/1 mUIpp

RMS Range II/Resolution . . . . . . . . . . . . . . . . . 0 to 16 UIpp/10 mUIpp

Built-in filters

as per Telcordia GR-253, ANSI T1.105.03, ITU-T O.172, G.825, G.813
High-pass filters . . . . . . . . . . . . . . . . . . . . . . . . . . 5 kHz, 12 kHz, 1 MHz

Low-pass filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 MHz

The high-pass filters can be switched off.

Frequency range without high-pass filter

Meas. range I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Hz

Meas. range II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Hz

14

A4

A3

A2

A1

UIpp

f0

f1

f2

f3

f4

Jitter frequency (log)