beautypg.com

Atec Acterna-JDSU-ANT-20SE User Manual

Page 18

background image

Automatic limit testing of

Maximum Tolerable Wander, MTW

ITU-T G.823, G.824

The ANT-20SE tests the device under test for conformance to the

standard tolerance mask limits for maximum tolerable wander.

Measurement poinits . . . . . . . . . up to 10 Frequency/Amplitude values

Detection criteria . . . . . . . . . . . . . . . . . . . . . . . . . TSE (bit error), alarms

Frequency range . . . . . . . . . . . . . . . . . . . . . 10 mHz to 10 Hz, step 1 mHz

Amplitude range . . . . . . . . . . . . . . . . . . 0.1 to 200 000 UI, step: 0.1 UI

The result of each measurement is shown in a table with an ªOKº or

ªFAILEDº message.

Accessory

Acterna TSR-37

DA 3700/00

Rubidium Timing Signal Reference

The TSR-37 is a powerful reference source to quickly measure and test

the synchronization quality of PDH/SDH/SONET digital networks.

MTIE and TDEV measurements for up to 1000 seconds can be easily

performed without a GPS reference. Coupled with the optional

GPS-FC, the range of observation time can be largely extended to meet

specific requirements.

Provides the reference clock for wander analysis using the ANT-20.

. PDH/SDH/SONET Wander measurement source

. Accuracy at 25 C: +5610

±11

without GPS

51610

±11

with GPS

. 12 outputs, framed and unframed:

5 MHz, 10 MHz, 2.048 kHz, 1.544 kHz, E1, T1

. Compact, robust & lightweight

. External autocalibration input

. Input for GPS or Cesium reference

See Acterna TSR-37 data sheet for details.

18