46

Displayed error

Meaning

Possible causes

Suggested solutions

Low Batt Z__

No battery power supply
in zone __.

x

The battery capacity in the detector of zone
__ is almost exhausted.

x

Change the detector battery within 14 days.

WAM__ SUP Fail

Supervision signal from
the accessory module
has failed.

x

The accessory module outside the wireless
range of the system.

x

The wireless unit on the accessory module
has failed.

x

Check wireless communication between the
system and the accessory module using the
wireless testing box.

x

Install the accessory module in a more suitable
location.

x

Contact your installer.

Zone Supervision
Faults

Supervision signal from
detector of zone __ has
failed.

x

The detector is outside the wireless range
of the system.

x

The wireless unit of the detector has failed.

x

Check wireless communication between the
system and the transmitter using the wireless
testing box.

x

Install the detector in a more suitable location.

x

Contact your installer.

Jamming

Jamming of wireless
communication for more
than 30 seconds inside a
minute.

x

Intentional or natural disturbance within the
wireless band.

x

Contact your installer.

PSTN Line Fault

Analogue transmission
path has failed.

x

The analogue telephone connection is not
connected correctly to the telephone line.

x

The transmission path has been
programmed for an analogue telephone,
although this is not used.

x

Check the correct connection of the analogue
telephone line.

x

Check whether the analogue line is engaged for
a long period or disconnected.

x

Contact your installer. Programming must be
changed.

PLGON Line Fault

Digital transmission path
has failed.
Failure of GSM
connection.

x

The ISDN telephone connection is not
connected correctly to the telephone line.

x

The GSM device is not connected to the
network.

x

Check the correct connection of the ISDN
telephone line.

x

Check that the SIM card is correctly inserted and
that you still have credit.

x

Use the “About Comms” item in the user menu
to check the signal strength and the state of the
GSM module. If the signal strength is too weak,
no transmission can take place.