beautypg.com

Technical bulletin, Ts550 evo – Franklin Fueling Systems Colibri: Connecting a T5 Series Fuel Management System or Colibri Tank Monitor to an ALVIC SCS3 Point of Sale System User Manual

Page 2

background image

7.55"

RADIUS

11.70"

5.80"

3.00"

RISER/COLUMN PIPE

DISCHARGE/LEAK DETEC TO R

CENTERLINE

CENTERLINE

LINE TEST PO RT

10.45"

8.12"

RADIUS

UP FOR SE

R VICE

DOWN FOR TEST

LINE

PRESSURE

TEST

R

E

C

E

L

E

T

R E

MO

VIN

G

CO

VE

R

TIG

HT

R

D

I

R

E

'

V

E

L

N

V

U

O

C

R

N

C

A V

L E

A

V

U

O

T

I

I

U

K E

E P

CO

VE

R

B E

FO

R E

OP

E N

CI

R C

UI

T

E

L

C

R

OP

E N

CIR

CU

IT

R E

MO

VIN

G

CO

VE

R

B E

FO

R E

E

CO

VE

R

TIG

HT

K E

E P

V

R

E

U

O

C

U

I

LC

T

E N

'D

C

L

N

V A

A

E

E V

E

L

R

R

I

E

L

T

C

RI

V R

OU

8.00"

5.75"

6.75"

6.31"

3.31"

4.94"

11.00"

6.31"

3.13"

3" PIPE PLUG IF ONL

Y ON

E

SIDE OF MANIFOLD USED

(FURNISHED BY CUST

OMER)

CA

L MAKEUP

POINT (1" NPT

)

TANK PO

RT

TECHNICAL

BULLETIN

For Tank Monitor Reconciliation and Auto Calibration

If reconciliation is necessary by the Tank Gauge monitor, besides activating reconciliation as it was explained before, you

should program the dispensers as it is shown next:

In the figure above, you can see an example of a reconciliation configuration, where the relationship between the hose,

dispenser, and tank is shown. In this way hose number 1 from dispenser 1 uses tank 1, and the hose number 1 from

dispenser 4 uses tank 3.
Also this figure belongs to the table grid equivalence between ALVIC and Franklin Fueling Systems T5 and Colibri tank

monitors, the red highlighted figures references the tank gauge setup.

• When it says, Surtidor ID = 1, This dispenser is from the SCP not the console.
• When it says, Manguera ID = 1, This hose is from the SCS.
• What it is inside the node it references the tank gauge console setup.

On the T5 Series or Colibri Tank Monitor

• A standard CAT5 cable is used for a direct network connection from switch / router to the T5 Series Ethernet port.
• Confirm the port programming in the T5 Series Setup.

TS550 / 5000 / Colibri

• System-Configuration-Protocol Settings

Protocol

Settings

Veeder-Root Port

8001

Veeder-Root Client Timeout

0

Web Server Secondary Port

10001

TS550 evo

• Setup-Parameters-Communications-Protocols

Communications
Serial

Ports

...

...

Modem

Type

None

Protocols

Veeder-Root

Port

Veeder-Root Client

Timeout

8001