beautypg.com

Installing the mtp t 15hd a wm and mtp t 15hd a d, Preparing the site and installing the wall box, Installing the mtp t 15hd a wm and – Extron Electronics MTP T 15HD A AAP User Guide User Manual

Page 9: Mtp t 15hd a d, Installation

background image

MTP T 15HD A Architectural Plates • Installation

Installation

5

Installing the MTP T 15HD A WM and

MTP T 15HD A D

The MTP T 15HD A WM and MTP T 15HD A D can be installed

in a one-gang electrical wall box, with the MTP T 15HD A D

fitting into a Decora wall plate cover (supplied). If a suitable

wall box is already installed, follow steps 5 through 8 below. To

install a new wall box, follow all the steps below. Underwriters

Laboratories (UL) Listed wall boxes are recommended.
The installation must conform to national and local electrical

codes and to the wall plate’s size requirements.
The following Underwriters Laboratories (UL) requirements

pertain to the installation of the MTP T 15HD A architectural

series into a wall or furniture.
1.

These units are not to be connected to a centralized DC

power source or used beyond their rated voltage range.

2.

These units must be installed in UL listed junction boxes.

3.

These units must be installed with conduit in accordance

with the National Electrical Code

Preparing the site and installing the wall box

Choose a location that allows cable runs without interference.

Allow enough depth for both the wall box and the cables. The

box should be at least 2.5 inches (6.4 cm) deep to accommodate

the connectors and cables. Install the cables into the wall,

furniture, or conduits before installing the wall plate.
1.

If a wall box is not available to use for a template, use the

template on page 13. If installing directly into furniture,

cut out the center portion of the template.

2.

Place the template (or the wall box) against the installation

surface, and mark the guidelines for the opening.

3.

Cut out the material from the marked area.

4.

Insert the wall box into the opening. The box or the wall

plate’s rear connectors should fit easily into the opening.

Enlarge or smooth the edges of the opening as needed.

5.

With the power supply disconnected, feed cables for the

output devices through the opening and through the wall

box punch-out holes, securing them with cable clamps to

provide strain relief.

6.

Trim back and/or insulate exposed cable shields with heat

shrink to reduce the chance of short circuits.

To prevent short circuits, the outer foil shield can be cut

back to the point where the cable exits the cable clamp.

This manual is related to the following products: