Tp cable termination, Figure 12 — tp cable termination – Extron Electronics MTP T 15HD A AAP User Guide User Manual
Page 16

MTP T 15HD A Architectural Plates • Installation
12
TP Cable Termination
N
RJ-45 termination with CAT 5, CAT 5e, or CAT 6 cable
must comply with the TIA/EIA T 568A or TIA/EIA T 568B
wiring standards for all connections.
RJ-45 termination with Skew-Free A/V UTP cable must
comply with TIA/EIA T 568 A only.
Figure 12 details the recommended termination of TP cables
with RJ-45 connectors in accordance with the TIA/EIA T 568A or
TIA/EIA T 568B wiring standards. You can use either standard
with CAT 5 cable, but ensure that you use the same standard on
both ends of the cable.
1&2
3&6 4&5
7&8
Twisted Pairs (4)
12345678
Pins:
Pin
Signal
1
Red+/V. sync+
2
Red-/V. sync-
3
Green/H. sync+
4
Blue+/H. sync+
5
Blue-/H. sync-
6
Green/H. sync-
7
Mono audio+
8
Mono audio-
Wire color
White-green
Green
White-orange
Blue
White-blue
Orange
White-brown
Brown
Wire color
TIA/EIA T 568 A TIA/EIA T 568 B
White-orange
Orange
White-green
Blue
White-blue
Green
White-brown
Brown
Figure 12 — TP cable termination
N
Enhanced Skew-free A/V cable is not recommended for
Ethernet/LAN applications.
This cable is specially designed for compatibility with
Extron Twisted Pair products that are wired using the
TIA/EIA 568 A standard.
The green, brown, and blue pairs of this cable have
virtually identical lengths and should be used to
transmit the RGB signals.
The orange pair of this cable has a different length and
should not be used to transmit the RGB signals.