beautypg.com

Removing and installing a fan, Fans – Extron Electronics MTPX Plus 6400 Series Setup Guide User Manual

Page 29

background image

ANAHEIM,

CA

RESET

RS232/RS422

REMO

TE

LAN

ACT

LINK

100-240V
50/60Hz
6.4A MAX.

100-240V
50/60Hz
1.2A MAX.

REDUND

ANT

PRIMAR

Y

LISTED

1T23

US

®

N15779

FAN ASSEMBL

Y

29

30

31

32

RS-232 OUTPUT INSER

TION

AUDIO INPUTS

L

R

1

L

R

2

L

R

3

L

R

4

L

R

5

L

R

6

Tx

Rx

1

Tx

Rx

2

Tx

Rx

3

Tx

Rx

4

Tx

Rx

5

Tx

Rx

6

Tx

Rx

7

Tx

Rx

8

42

43

44

45

46

47

48

54

55

56

57

58

59

60

61

62

63

64

L

R

7

L

R

8

MONO AUDIO OUTPUTS

L

R

1

L

R

2

L

R

3

L

R

4

L

R

5

L

R

6

L

R

7

L

R

8

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

OUTPUTS

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

Tx

Rx

9

Tx

Rx

10

Tx

Rx

11

Tx

Rx

12

Tx

Rx

13

Tx

Rx

14

Tx

Rx

15

Tx

Rx

16

PRIMAR

Y PO

WER SUPPL

Y 1

PRIMAR

Y PO

WER SUPPL

Y 2

REDUND

ANT PO

WER SUPPL

Y 1

REDUND

ANT PO

WER SUPPL

Y 2

Power
LED

Align with Plastic Guides

Knurled Knobs

Removing and Installing a Fan

The MTPX Plus 6400 switchers have three fan modules. The top two
fan modules are identical; the bottom fan module is unique. If a fan
fails, it should be replaced at the earliest opportunity.

NOTE: The fans modules are hot-swappable. Any fan can

be removed or installed without powering down the
switcher.

1.

Rotate the top and bottom knurled knobs to completely loosen
the captive screws.

2.

Gently pull on the screws to loosen the fan from the backplane.

3.

Slide the fan out of the chassis.

4.

Orient the fan to be installed so that the printing on the back of
the panel is right-side up.

5.

Align the flanges on the fan with the top and bottom fan guides
(see the next page).

6.

Gently slide the fan into the enclosure until the fan meets
resistance.

7.

Gently seat the fan in the backplane.

8.

Use a screwdriver to tighten the top and bottom knurled knobs/
captive screws to lock the fan in place.

ANAHEIM,

CA

RESET

RS232/RS422

REMO

TE

LAN

ACT

LINK

100-240V

50/60Hz
6.4A MAX.

100-240V

50/60H

z

1.2A MAX.

REDUND

ANT

PRIMAR

Y

LISTED

1T2

3

US

®

N15779

FA

N ASSEMBL

Y

FA

N ASSEMBL

Y

LOC

AL INPUTS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

RS-232 OUTPUT INSER

TION

INPUTS

AUDIO INPUTS

L

R

1

L

R

2

L

R

3

L

R

4

L

R

5

L

R

6

Tx

Rx

1

Tx

Rx

2

Tx

Rx

3

Tx

Rx

4

Tx

Rx

5

Tx

Rx

6

Tx

Rx

7

Tx

Rx

8

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

2

1

3

4

5

6

LOC

AL OUTPUT

S

7

8

INPUT

SELEC

T

LOC

AL

1 2

3 4

RJ-4

5

2

1

3

4

INPUT

SELEC

T

LOC

AL

5 6

7 8

RJ-4

5

L

R

7

L

R

8

MONO

AUDIO OUTPUTS

L

R

1

L

R

2

L

R

3

L

R

4

L

R

5

L

R

6

L

R

7

L

R

8

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

OUTPUT

S

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

Tx

Rx

9

Tx

Rx

10

Tx

Rx

11

Tx

Rx

12

Tx

Rx

13

Tx

Rx

14

Tx

Rx

15

Tx

Rx

16

PRIMAR

Y PO

WER SUPPL

Y 1

PRIMAR

Y PO

WER SUPPL

Y 2

REDUND

ANT PO

WER SUPPL

Y 1

REDUND

ANT PO

WER SUPPL

Y 2

Align with Plastic Guides

Knurled Knobs

FAN ASSIMB

LY

48

MTPX Plus 6400 • Maintenance and Modifications

49

MTPX Plus 6400 • Maintenance and Modifications