Saving or recalling a preset, Setting the front panel locks (executive modes), Executive modes) – Extron Electronics MTPX Plus 6400 Series Setup Guide User Manual
Page 12
4.
Press and release the desired output buttons.
3 4
ENTER
8
Amber indicates video and audio tie.
Green indicates video only tie.
Red indicates audio only tie.
Green indicates the
need to confirm the
change.
5.
Press and release the Enter button. All button indicators turn off.
Saving or Recalling a Preset
A "preset" is a configuration that has been stored.
1.
Save a preset — Press and hold the Preset button until it flashes.
PRESET
PRESET
The Preset button blinks.
Press and
hold.
2 seconds
Save a
preset
Recall a preset — Press and release the Preset button.
PRESET
PRESET
1 2 3 4 5 6
16
15
Recall a
preset
The Preset button lights.
Press and release.
All input and output buttons with assigned presets light
red.
When a preset is
saved
, the configuration data at
assigned preset locations is overwritten.
INPUTS
2.
Press and release the desired input or output button.
1
ENTER
The button blinks
red to indicate that
this
preset is selected to save or recall.
The Enter button blinks
red to indicate the need to
activate the save or recall.
3.
Press and release the Enter button.
Setting the Front Panel Locks (Executive Modes)
The matrix switcher has three levels of front panel security lock that
limit the operation of the switcher from the front panel. The three
levels are:
Lock mode 0 — The front panel is completely unlocked.
Lock mode 1 — All changes are locked from the front panel
(except for setting Lock mode 2). Some functions can be viewed.
Lock mode 2 — Basic functions are unlocked. Advanced functions
are locked and can be viewed only.
Basic functions consist of:
•
Making ties
•
Saving and recalling presets
•
Setting input audio gain and attenuation
•
Changing Lock modes
Advanced functions consist of:
•
Setting audio output mutes
•
Setting audio output volume
•
Setting audio/RS-232 wire pair and front panel configuration
The switcher is shipped from the factory in Lock mode 2.
Selecting Lock Mode 2 or Toggling Between
Mode 2 and Mode 0
NOTES:
•
If the switcher is in Lock mode 0 or mode 1, this
procedure selects mode 2.
•
If the switcher in in Lock mode 2, this procedure selects
mode 0 (unlocks the switcher).
Toggle the lock on and off by pressing and holding the Enter
button, the Video button, and the Audio button simultaneously for
approximately 2 seconds.
I / O
VIDEO AUDIO
ENTER
I / O
VIDEO
AUDIO
ENTER
Press and
hold simultaneously.
The buttons blink twice.
Release the buttons.
2 seconds
14
MTPX Plus 6400 • Front Panel Operations
15
MTPX Plus 6400 • Front Panel Operations