beautypg.com

Installation, Signal jumpers for generational compatibility – Extron Electronics MTP Series User Guide User Manual

Page 9

background image

MTP Series • Installation

3

Installation

This section describes the installation procedures, including:

Signal Jumpers for Generational Compatibility

Mounting Options

Panel Features and Connections

CAUTION: Installation and service must be performed by authorized personnel only.

Signal Jumpers for Generational Compatibility

Over time, the MTPs have been redesigned, affecting the signal content of the TP cable wire
pairs, changing the audio from stereo to mono, and eliminating the remote power capability.
The new-generation units are not compatible with the old generation unless an internal
jumper in the new unit is shifted.
Shift the jumpers for the new transmitter, receiver, or both if:

Your installation mixes a transmitter and receiver from different generations.

You want the units to transmit stereo audio.

You want one unit to remotely power another.

Use the table below to identify the generation (revision level) of the transmitter and receiver
in your installation. If any of the above scenarios are true, reconfigure the jumpers for the
units before mounting the units.

NOTE:

Only the new generation units have these jumpers.

Transmitter

Old Generation
Part Number

New Generation
Part Number

MTP T SV A

60-540-22

60-540-52

MTP T SV A RCA

60-541-32

60-540-62

MTP T SVA AAP

70-362-02, -03

70-362-22, -23

MTP T AV

60-540-21

60-540-51

MTP T AV RCA

60-540-31

60-540-61

MTP T AV AAP

70-361-02, -03

70-361-22

Receiver

Old Generation
Part Number

New Generation
Part Number

MTP R SV A

60-541-22

60-541-52

MTP R SV A RCA

60-541-32

60-541-62

MTP R AV

60-541-21

60-541-51

MTP R AV RCA

60-541-31

60-541-61