Integration Scaling Matrix Switcher • Ethernet Connection

Escape character and Esc key

When Telnet is first started, the utility advises that the Escape character is ‘Ctrl+]’.
Many SIS commands include the keyboard

Esc

key. Consequently, some confusion

may exist between the Escape character and the Escape key.

The Telnet Escape character is a key combination, the

Ctrl

key and the

]

key

pressed simultaneously, that returns you to the Telnet prompt while leaving the
connection to the ISM intact.

The Escape key is the

Esc

key on the computer keyboard.

Local echo

Once connected to the ISM, by default Telnet does not display your keystrokes on
the screen. SIS commands are typed in blindly and the SIS responses are displayed
on the screen. To command Telnet to show keystrokes, at the Telnet prompt, type
set local_echo and then press [Enter] before you open the connection to the switcher.

With local echo turned on, keystrokes and the switcher’s response are displayed on
the same line. For example: 1*1!In1 Out1 All, where 1*1! is the SIS command and
In1 Out1 All

is the response.

With local echo turned on, all keystrokes are displayed, even those that should be
masked, such as the password entry. For example, when entering a password with
local echo turned on, you will see a display such as a*d*m*i*n*, where admin is
the keyed in password and ***** is the masked response.

Local echo can be turned off by typing unset local_echo and then pressing [Enter] at
the Telnet prompt. If you are connected to the ISM and need to access the Telnet
prompt to turn local echo off, type the Escape character (

Ctrl

+

]

).

Set carriage return-line feed

Unless commanded otherwise, Telnet transmits a line feed character only (no
carriage return) to the connected ISM when you press the

Enter

key. This is the

correct setting for SIS communication with the switcher. The Telnet set crlf
command forces Telnet to transmit carriage return and line feed characters when

Enter

is pressed, but if crlf is set, the SIS link with the switcher will not function

properly.

Close

To close the link to the switcher, access the Telnet prompt by typing the Escape
character (

Ctrl

+

]

). At the Telnet prompt, type close and then press [Enter].

Help

For Telnet command definitions, at the Telnet prompt, type ? and then press
[Enter].

Quit

Exit the Telnet utility by typing quit and then press [Enter] at the Telnet prompt. If
you are connected to the ISM, access the Telnet prompt beforehand by typing the