Programmer’s guide, cont’d – Extron Electronics ISM 182 User Manual
Page 60
![background image](/manuals/311947/60/background.png)
Programmer’s Guide, cont’d
Integration Scaling Matrix Switcher • Programmer’s Guide
4-16
Command
Hex Command
Response
Additional description
(host to switcher)
(switcher to host)
Memory backup
Read
all memory contents
90 91
{8226 data bytes+1 byte checksum} Upload (switcher to control
device) all color, tint, contrast,
brightness, detail, sizing, and
centering settings; all user presets;
and all auto memories for all
inputs and both outputs.
Write
all memory contents
90 92+8226 data bytes+1 byte checksum
Dn1
Download (control device to
switcher) all color, tint, contrast,
brightness, detail, sizing, and
centering settings; all user presets;
and all auto memories for all
inputs and both outputs.
Read
partial contents
X2
90 93
{26 data bytes+1 byte checksum}
Upload (switcher to control
device) color, tint, contrast,
brightness, detail, sizing, and
centering settings; all user presets;
and all auto memories for the
input selected for output
X2
.
Write
partial contents
X2
90 94+26 data bytes+1 byte checksum
Dn1
Download (control device to
switcher) color, tint, contrast,
brightness, detail, sizing, and
centering settings; all user presets;
and all auto memories for the
input selected for output
X2
.
Command/response table for advanced instruction set
commands
The advanced instruction set consist of four hexadecimal commands for uploading
and downloading all or a portion of the switcher’s memory. These commands are
for use by knowledgeable programmers, and result in a dump of data from
(upload) or to (download) the switcher. Programmers can use the commands to
exactly duplicate the settings among switchers with a minimum of effort.