Extron Electronics IPL T S Series User Guide User Manual

Page 53

background image

4-13

IPL T S Series • Communication and Control

Command

ASCII (T

elnet)

(host to unit)

URL Encoded (W

eb)

(host to unit)

Response

(unit to host)

Additional description

Set verbose mode

24

E

X2@

CV

}

W

X2@

CV

|

V

rb

X2@

]

Enable or disable the verbose mode via this

command. For

X2@

:

0

=

cl

ea

r/

no

ne

, d

ef

au

lt

fo

r T

el

ne

t c

on

ne

ct

io

ns

;

responses ar

e not echoed to the host

1 = verbose mode is on, default for RS-232

host contr

ol; r

esponses ar

e echoed to the

host and displayed to the user

2 = send tagged r

esponses for queries

3 = verbose mode is on and tagged

responses ar

e sent for queries.

N

If

tagged

r

esponses

ar

e

enabled,

all

r

ead

commands

r

eturn

the

constant

string

+

data,

the

same

as

for

setting

a

value.

For

example,

for

E

CN

}

, the

r

esponse

is

Ipn•

X1@]

rather

than

just

the

data.

N

V

erbose

mode

is

a

communication

mode

in

which

the

device

r

esponds

with

mor

e

information

than

it

usually

would—mor

e

than

the

device,

itself,

r

equir

es.

For

example,

the

contr

oller

can

send

out

unsolicited

information

(such

as

notice

of

a

volume

or

input

change

or

a

change

in

some

other

setting).

That

is

an

example

of

a

verbose

(wordy)

r

elationship

between

the

contr

oller

and

a

connected

device.

V

erbose

mode

cr

eates

mor

e

network

traffic

than

usual,

which

can

slow

down

network

performance.

V

erbose

mode

is

usually

enabled

for

tr

oubleshooting

and

disabled

for

daily

use.

For

a

dir

ect

RS-232

connection,

the

contr

oller

is

set

for

verbose

mode

by

default.

When

the

IPL

T

S

device

is

connected

via

Ethernet,

verbose

mode

is

disabled

(by

default)

in

order

to

r

educe

the

amount

of

communication

traffic

on

the

network.

If

you

want

to

use

the

verbose

mode

with

a

contr

oller

connected

via

Ethernet,

this

mode

must

be

set

to

“on”

each

time

you

r

econnect

to

the

contr

oller

.

V

iew verbose mode

E

CV

}

WCV

|

X2@

]

Set br

oadcast mode

E

X6$

,

X1$

EB

}

W

X6$

%2C

X1$

EB

|

Bmd

X6$

,

X1$

]

This command details how often and

to what subnet work the IPL

T S unit

br

oadcasts a message.

X6$

= Br

oadcast r

epetition interval

in s

ec

on

ds

(0

to

2

55

[4

.2

5

m

in

ut

es

],

de

fa

ul

t =

0

=

o

ff

).

X1$

= IP

addr

ess (xxx.xxx.xxx.xxx). Leading

zer

os in each of four fields ar

e optional in

setting values, and they ar

e suppr

essed in

returned values.

Default br

oadcast addr

ess: 255.255.255.255.

Set br

oadcast mode to

the default addr

ess

E

X6$

EB

}

W

X6$

EB

|

Bmd

X6$

,255.255.255.255

]

Clear br

oadcast

mode

24

E

0EB

}

W0EB

|

Bmd

000,255.255.255.255

]

This command sets the r

epeat interval to

zer

o, turning of

f the br

oadcast mode.

V

iew br

oadcast mode

E

EB

}

W

EB

|

X6$

,

X1$

]

Set br

oadcast port and

MAC

E

{port#}*

X7!

,

X7@

PB

]

W{port}*

X7!

,

X7@

PB

|

Bpt{port#}*

X1*]