beautypg.com

Extron Electronics IN31608 User Manual

Page 19

background image

16

IN31608 OPERATION MANUAL - REV 1.6 1/4/01

2001 - INLINE, Inc.

COMMAND

DESCRIPTION

RESPONSE

PTgOooIii
(Matrix Mode)

Execute a switch in Matrix Mode. Connect Output mm to Input nn for Group g.
See CNF Command for reference.

g: Group #, a 1 byte ASCII code, 1 <= g <= 3.

ii: Input #, a 2 byte ASCII code, 00 <= ii <= 16.

If nn = 00, no input is selected, resulting in a blank output.

oo: Output #, a 2 byte ASCII code, 00 <= oo <= 8.

Example: [PT 1 O 04 I 02] (spaces added for clarity)

Connect Output #4 to Input #2 for the boards in Group 1.

[OK]

RGBx.x

Set RGB delay to x.x seconds. x.x: ranges from 0.0 to 6.0 in 0.1 second
intervals.
Example: [RGB3.7] Set RGB delay to 3.7 seconds.

[OK]

SAVExx
(Matrix Mode)

Save current configuration to SETUPxx
xx
: 2 byte ASCII code, 01 <= xx <= 16.
Example: [SAVE16] Set current configuration to Setup Memory 16.
Note: See [CALLxx]

[OK]

STAT0

General status request

See examples on pages 15 & 16

STAT1

Video array status request

See examples on pages 15 & 16

STAT2

Sync array status request

See examples on pages 15 & 16

STAT3

Audio array status request

See examples on pages 15 & 16

STAT4

Audio input volume array status request

See examples on pages 15 & 16

STAT5

Audio output volume array status request

See examples on pages 15 & 16

STAT6

Audio mute array status request

See examples on pages 15 & 16

STAT7
(Direct Mode)

Direct Mode switch matrix request

See examples on pages 15 & 16

STAT8

Projector Port status request

See examples on pages 15 & 16

STAT9

Serial Command Port status request

See examples on pages 15 & 16

SW (Matrix Mode)

Execute all switch connections as defined by the L command.

[OK]

VIS0

Disable genlock operation / vertical interval switching

[OK]

VIS1

Enable genlock operation / vertical interval switching

[OK]

VOLo+

Increment volume for output o, 1 <= o <= 8. In Direct Mode the [VOLo+]
command controls all outputs simultaneously regardless of the ‘o’ channel
selection.
Example: [VOL3+]
In Matrix Mode increment volume for output 3 by one to a maximum
value of 255. In Direct Mode increment volume for all outputs by one to
a maximum value of 255.
Note: see [MDVOL0] & [MDVOL1]

[OK]

VOLo-

Decrement volume for output o, 1 <= o <= 8. In Direct Mode the [VOLo-]
command controls all outputs simultaneously regardless of the ‘o’ channel
selection.
Example: [VOL6-]
In Matrix Mode decrement volume for output 6 by one to a minimum
value of 0. In Direct Mode decrement volume for all outputs by one to a
minimum value of 0.
Note: see [MDVOL0] & [MDVOL1]

[OK]

VOLoxxx

Set the output volume for both left and right channels of output ‘o’ to value ‘xxx’.
1 <= o <= 8; 000 <= xxx <= 255 decimal.
In Direct Mode the [VOLoxxx] command controls all outputs simultaneously
regardless of the ‘o’ channel selection.
Example: [VOL6255]
In Matrix Mode set volume for output 6 to a value of 255. In Direct

Mode set volume for all outputs to a value of 255.

Note: see [MDVOL0] & [MDVOL1]

[OK]