Power On Settings

The IN31608 utilizes Power On settings to access certain parameters of the unit. To access a Power On
adjustment, you must depress a specific button while turning the unit’s power switch to ON. If power is already
on, the user can hold down the indicated button and switch the power off and then back on.

IN31608 POWER ON OPTIONS

F1

Factory Default Setting

BLANK Blank

Factory

Default

Setting

MUTE

Toggle Front Panel Enable

MODE

Front Panel Test Mode

SAVE

Toggle Mode (Matrix / Direct)

OUT1

Direct Mode Setup

OUT2

Load Projector Code Memories with Test Strings

OUT3

Clears the Projector Port Memories

OUT4

Enable Genlock operation / vertical interval switching

INPUT1

Set RGB Delay to 0.0 seconds

INPUT2

Set RGB Delay to 0.5 seconds

INPUT3

Set RGB Delay to 1.0 seconds

INPUT4

Set RGB Delay to 1.5 seconds

INPUT5

Set RGB Delay to 2.0 seconds

INPUT6

Set RGB Delay to 2.5 seconds

INPUT7

Set RGB Delay to 3.0 seconds

INPUT8

Set RGB Delay to 3.5 seconds

INPUT9

Set RGB Delay to 4.0 seconds

INPUT10

Set RGB Delay to 4.5 seconds

INPUT11

Set RGB Delay to 5.0 seconds

INPUT12

Set RGB Delay to 5.5 seconds

INPUT13

Set RGB Delay to 6.0 seconds

RESET TO FACTORY DEFAULT (F1), (BLANK)

To reset the unit to the factory default setting, hold down the F1 or BLANK button while turning on the unit.
The factory default settings are as follows:

Parameter

Default State

Front Panel Operation

Enabled

RGB Delay

0.0 secs.

Audio Levels

Normalized to Default, -3 dB.
Input = 128, Output = 52

Serial Control Port

9600 baud, 8 data, no parity

Command Code:

[ ]

Projector Control Port

RS-232, 9600 baud, 8 data, no parity

Group 1

All Boards

Group 2

No Boards

Group 3

No Boards

Code Delay

0 msecs.

Vertical Interval Switching /
Genlock Operation

Disabled