Error responses, Using the command/response tables, Error responses using the command/response tables – Extron Electronics FOXBOX Tx_Rx DVI Plus User Guide User Manual
Page 28

Error Responses
When the unit receives a valid SIS command, it executes the command and sends a response
to the host device. If the unit is unable to execute the command because the command is
invalid or it contains invalid parameters, the unit returns an error response to the host. The
error response codes are:
E10
-
Invalid command
E11
-
Invalid preset number
E13
-
Invalid parameter
E14
-
Invalid command for this configuration
Using the Command/Response Tables
The command/response table begins on the next page. Either uppercase or lower case letters
are acceptable in the command field except where indicated for the audio level (gain and
attenuation) commands. Symbols are used throughout the table to represent variables in
the command/response fields. Command and response examples are shown throughout the
table. The ASCII to HEX conversion table below is for use with the command/response table.
ASCII to Hex Conversion Table
•
Space
FOXBOX Tx/Rx • Remote Control
22