Simple instruction set control, Host-to-unit instructions, Symbol definitions – Extron Electronics FOXBOX Tx_Rx DVI Plus User Guide User Manual
Page 26: Host-to-unit instructions symbol definitions
![background image](/manuals/311766/26/background.png)
Simple Instruction Set Control
Host-to-Unit Instructions
SIS commands consist of one or more characters per field. No special characters are required
to begin or end a command character sequence. When a command is valid, the unit
executes the command and sends a response to the host device. All responses from the unit
to the host end with a carriage return and a line feed (CR/LF = ]), which signals the end of
the response character string. A string is one or more characters.
Symbol Definitions
]
= CR/LF (carriage return/line feed)
}
= Carriage return (no line feed)
•
=
Space (hard) character
E
= Escape key (hex 1B)
X!
= Mute/auto memory status
0 = off
1 = on
X@
= Resolution
01 = 1920 x 1200
11 = 576p
02 = 800 x 600
12 = 720p
03 = 1024 x 768
13 = 1080i
04 = 1280 x 768
14 = 1080p
05 = 1280 x 1024
15 = 640 x 480
06 = 1365 x 768
16 = 1440 x 900
07 = 1366 x 768
17 = 1280 x 800
08 = 1400 x 1050
18 = 1680 x 1050
09 = 1600 x 1200
19 = 1360 x 768
10 = 480p
X#
= Refresh rate
1 = 50 Hz
2 = 60 Hz
X$
= Mode switch position
0 = off (down)
1 = on (up)
X%
= Output sync format
0 = RGBHV
1 = RGsB
X^
= Output sync polarity
0 = follows input
1 = force sync negative
X&
= Horizontal and vertical position
000 through 255
X*
= Horizontal start
000 through 255
X(
= Pixel phase
00 through 31
X1)
= Total pixels
± 255 of default value for selected resolution
X1!
= Sync frequency
xxx.xx (frequency in kHz [H] or Hz [V])
X1@
= Memory preset number
01 to 30
X1#
= Audio gain adjustment range
00 to 10
X1$
= Audio level adjustment range
–18 to +10 (in 1.0 dB steps)
X1%
= Audio attenuation adjustment range
00 to 18
X1^
= Audio output level
0 = consumer (–10 dBV)
1 = professional (+4 dBu)
X1&
= Test pattern
0 = none
2 = grayscale
1 = color bars
3 = alternating pixels
X1*
= Video shutdown interval
0 = 0 seconds (off)
4 = 1 second
1 = 0.25 second
5 = 1.25 second
2 = 0.5 second (default)
6 = 1.5 second
3 = 0.75 second
X1(
= Rx link enable
0 = disable
1 = enable (default)
X2)
= Link and input status
0 = link or input not sensed
1 link or input sensed
X2!
= Transmission mode
SM = singlemode
MM = multimode
X2@
= Transmitter or receiver
Tx = transmitter
Rx = receiver
X2#
= Firmware version
v.vv
X2$
= Internal temperature
nnnF•nnC
FOXBOX Tx/Rx • Remote Control
20