Status tab – Extron Electronics FOX RS 104 User Guide User Manual
Page 24
FOX RS 104 RS-232 Inserter • Remote Control
18
NOTE: A User name entry is not required.
6.
Click in the
Password
field and type in the appropriate administrator or user password.
Click the
OK
button.
The inserter checks several possibilities, in the following order, and then responds
accordingly:
•
Does the address include a specific file name, such as
10.13.156.10/<file_name>.html?
If so, the inserter downloads that HTML page.
•
Is there a file in the inserter memory that is named “index.html”?
If so, the inserter downloads “index.html” as the default startup page.
•
If neither of the above conditions is true, the inserter downloads the
factory-installed default startup page, “nortxe_index.html” (see figure 10), also
known as the System Status page.
Status Tab
System Status page
The System Status page (see figure 10) provides an overall view of the status of the inserter,
including each of the four insertion ports. The System Status page is the default page that
the inserter downloads when you connect to it. Access the System Status page from other
pages by clicking the
Status
tab.
Figure 10.
System Status Page
The status web page periodically updates itself to reflect the latest status of the inserter
components. If a value changes, the display shows the change in status the next time it
updates.