background image

FOX RS 104 RS-232 Inserter • Remote Control

14

X1#

= Number of open connections

0 – 200

X1$

= Password

12 alphanumeric characters

NOTE: The HTML language reserves certain characters for specific functions (see “

Special Characters

” on page 28).

X1%

= DHCP

0 =off, 1 = on

X1^

= Baud rate

9600, 19200, 38400, 115200

X1&

= Parity

odd, even, none, mark, space (Only the first letter required.)

X1*

= Data bits

7, 8

X1(

= Stop bits

1, 2

X2)

= Port type (always 0 = RS-232)

X2!

= Verbose mode

0 = clear/none (default for Telnet connection) 2 = tagged responses for queries
1 = verbose mode (default for RS-232)

3 = verbose mode and tagged for queries

NOTE:

If tagged responses is enabled, all read commands return the constant string and the value as the set command does

(for example, the read matrix name command,

E

CN

}

, returns Ipn•

X%]

).

X2@

= Port timeout interval (in 10-sec. increments)

1 (= 10 seconds) – 65000 (default is 30 = 300 seconds = 5 minutes)

X2#

= Direct access port map

0

(= disabled) or

1024

and up (default is

2001

)