3 operating procedures, 2 ir illuminator controls, 1 operating the cipher – Armasight DACCIPHBB01NTS1 Cipher Digital Night Vision Clip-on System User Manual
Page 31

31
3.2.2 IR ILLUMINATOR CONTROLS
The controls of the optional IR illuminators are shown in Figure 3-21 and defined in Table 3-3. The ITEM
NO. column indicates the number used to identify items in Figure 3-14.
1
2
FIGURE 3-21. IR ILLUMINATOR CONTROLS
TABLE 3-3. IR ILLUMINATOR CONTROLS
ITEM NO.
FUNCTION
DESCRIPTION
1
POWER SWITCH
Switches the IR illuminator on/off and adjusts for radiated power.
Four ON-positions are located between two OFF positions, and are
each marked with a different-sized spot. The larger the spot, the
greater the radiated power.
2
LENS FOCUS
Adjusts for IR beam divergence. Adjustment range is covered with
approximately one turn of the lens.
3.3 OPERATING PROCEDURES
3.3.1 OPERATING THE CIPHER
WARNING:
When installing the equipment on a weapon, verify that the weapon is clear and that the safety
is on before proceeding.
CAUTION:
DO NOT force the equipment controls past their stopping points.
CAUTION:
Although the Cipher is highly resistant to damage from light overload, DO NOT point it, either
powered or inoperative, directly at the sun or any other source of high-intensity light that the
unprotected human eye cannot tolerate (such as welding arc). To prevent inadvertent expo-
sure, never leave the equipment unsupervised with the objective lens cap removed.