3.2.2 IR-850 CONTROLS

The IR850 controls are shown in Figure 3-14 and defined in Table 3-2. The ITEM NO. column indicates the

number used to identify items in Figure 3-14.

TABLE 3-2. IR-850 CONTROLS

ITEM NO. CONTROL/INDICATOR

FUNCTION

1

Power Switch

Switches the IR850 on/ off and adjusts for radiated power. Four
on-positions are located between two OFF positions, and are each
marked with a different-sized spot. The larger the spot, the greater the
radiated power.

2

Lens

Adjusts for IR beam divergence. Adjustment range is covered with
approximately one turn of the lens.

3.3 OPERATING PROCEDURES

3.3.1 CO-LR OPERATING PROCEDURES

Operating procedures should be performed in night light conditions only.

CAUTION:

Use of the CO-LR in brightly lit conditions may damage the image intensifier.

CAUTION:

Pay attention to the caution notice on the objective lens cap: “do not remove in daylight.”

1. Verify that the battery is installed as required.
2. Perform a visual estimation of the illumination level in the viewing area, using the reference data

presented in Appendix A. You can begin operating the CO-LR if the illumination level is less than 1

lux.

3. Remove the objective lens cap and place it over the lens’ housing.