Data sheet, Isolation specifications, General specifications – GE Industrial Solutions JRCK017A0S32R0 Orca Series User Manual
Page 4: Feature specifications

GE
Data Sheet
JRCK017A0S32R0 Orca Series; DC-DC Converter Power Modules
36–62 Vdc Input; 32.0Vdc Output; 17.0Adc Output
October 11, 2013
©2012 General Electric Company. All rights reserved.
Page 4
Isolation Specifications
Parameter
Symbol
Min
Typ
Max
Unit
Isolation Capacitance
C
iso
15
nF
Isolation Resistance
R
iso
10
MΩ
General Specifications
Parameter
Device
Symbol
Min
Typ
Max
Unit
Calculated Reliability based upon Telcordia SR-332 Issue 2:
Method
I
Case 3 (I
O
=80%I
O, max
, T
A
=40°C, airflow = 200 lfm, 90%
confidence)
All
FIT 476.1
10
9
/Hours
MTBF 2,100,581 Hours
Weight All
76.4 (
2.69)
g (
oz.)
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Remote On/Off Signal Interface
(V
IN
=V
IN, min
to V
IN, max
; open collector or equivalent,
Signal referenced to V
IN-
terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low - Remote On/Off Current
All
I
on/off
1.0 mA
Logic Low - On/Off Voltage
All
V
on/off
0
1.2 V
dc
Logic High Voltage – (Typ = Open Collector)
All
V
on/off
5 V
dc
Logic High maximum allowable leakage current
All
I
on/off
50
μA
Turn-On Delay and Rise Times
(Vin=V
in,nom
, I
O
=I
O, max
, 25C)
Case 1: T
delay
= Time until V
O
= 10% of V
O,set
from application
of V
in
with Remote On/Off set to ON,
All
T
delay
120 ms
Case 2: T
delay
= Time until V
O
= 10% of V
O,set
from application of
Remote On/Off from Off to On with V
in
already applied for at
least one second.
All T
delay
20 ms
T
rise
= time for V
O
to rise from 10% of V
O,set
to 90% of V
O,set
. All T
rise
45 55 65 ms
Output Voltage Overshoot
3 %
V
O, set
(I
O
=80% of I
O, max
, T
A
=25°C)
Output Voltage Adjustment
(See Feature Descriptions):
Output Voltage Remote-sense Range
(only for No Trim or Trim down application )
All V
sense
__
__
2 %V
o,nom
Output Voltage Set-point Adjustment Range (trim)
All
V
trim
16.0 --- 35.2 V
dc
Output Overvoltage Protection
All
V
O, limit
37
39 V
dc
Over Temperature Protection
All
T
ref
110
°C
(See Feature Descriptions, Figure 17)
Input Under Voltage Lockout
V
IN, UVLO
Turn-on Threshold
All
35 36 V
dc
Turn-off Threshold
All
30.5 32.5
V
dc
Hysteresis All
3 V
dc
Input Over voltage Lockout
V
IN, OVLO
Turn-on Threshold
All
62
66
V
dc
Turn-off Threshold
All
66
68
V
dc
Hysteresis All
--- 3 --- V
dc