5! evse modbus diagnostic registers – GE Industrial Solutions WattStation Pedestal EVSE Charger MODBUS Register Mapping Guide User Manual
Page 20

WattStation
TM
EV Charger MODBUS Register Guide
20 GE Energy ©2012 GE Company All Rights Reserved
4.5
EVSE MODBUS Diagnostic Registers
EVSE SNTP Diagnostics Registers allow the user to view the EVSE MODBUS Diagnostics
data.
The
address offset for EVSE MODBUS Diagnostics registers is defined as 00xx0011FF55 (501 in Decimal
notation) in this version of MODBUS Register Map.
MODBUS Data Model: Input registers (Read only)
The
Module ID for EVSE MODBUS Diagnostics registers is defined as 00xx44.
Address
(hex)
MODBUS
Register
(dec)
Parameter
Data
Range
Description
Properties
Offset
501
EVSE MODBUS
Diagnostic
Register Validity
Indicate if the
MODBUS
Diagnostics
register is valid or
not.
0----Invalid
1----Valid
R
Offset+1
502
EVSE MODBUS
Diagnostic
Register Version
0x1000 High byte ----
main version.
Low byte ----
minor version.
The current
version of EVSE
MODBUS
Diagnostics
Register is 1.0.
R
Offset+2
503
MODBUS Service
Feature Selected
0-2
0- Disabled
1- Basic function
2- Full function
R
Offset+3
504
MB Version
Application
Version
R
Offset+4
505
Maximum
Number MODBUS
Connections
R
Offset+5
506
Number of
MODBUS
Requests
Received
Bytes 3 and 2
R
Offset+6
507
Number of
MODBUS
Requests
Received
Bytes 1 and 0
0-
65535
R
Offset+7
508
Number of
0-
R