GE Industrial Solutions WattStation Pedestal EVSE Charger MODBUS Register Mapping Guide User Manual
Page 15

WattStation
TM
EV Charger MODBUS Register Guide
15 GE Energy ©2012 GE Company All Rights Reserved
Register
Data Module
Information
Registers
Version
0x1000
EVSE MODBUS Data
Module Information
Register
High byte ---- main
version.
Low byte ---- minor
version.
The current version of
EVSE MODBUS Data
Module Information
Register is 1.0.
Offset+2
3
MODBUS
Register
Map Version
>=
0x1000
Indicate the version of
EVSE MODBUS Register
Map
High byte ---- main
version.
Low byte ---- minor
version.
The current version of
EVSE MODBUS Register
Map is 1.0.
R
Offset+3
4
Number of
MODBUS
Register
Data
Modules
1-65535
The number of data
modules defined in the
current version of EVSE
MODBUS Register Map,
including this data
module.
R
Offset+4
5
Data Module
1 ID
Indicate the ID of Data
Module 1.
R
Offset+5
6
Data Module
1 Offset
0x0000-
0xFFFF
Indicate the Address
offset of Data Module 1.
R
Offset+6
7
Data Module
1 Length
Indicate the number of
MODBUS Registers in the
data module 1.
R
…
…
…
…
…
…
Offset+2+3×N
2+3×N
Data Module
N ID
Indicate the ID of Data
Module N.
R
Offset+3+3×N
3+3×N
Data Module
N Offset
0x0000-
0xFFFF
Indicate the Address
offset of Data Module N.
R
Offset+4+3×N
4+3×N
Data Module
N Length
Indicate the number of
MODBUS Registers in the
data module N.
R
EVSE MODBUS Register Data Module Information Registers
Table - 4.1