GE Industrial Solutions WattStation Pedestal EVSE Charger MODBUS Register Mapping Guide User Manual
Page 19

WattStation
TM
EV Charger MODBUS Register Guide
19 GE Energy ©2012 GE Company All Rights Reserved
Charging
Voltage
Offset+7
348
Current
Charging
Consumed
Power (high
16 bit)
0-
65535
The high 16 bit
values of the current
charging consumed
power.
R
Offset+8
349
Current
Charging
Consumed
Power(low 16
bit)
0-
65535
The low 16 bit values
of the current
charging consumed
power.
The unit of power is
in Watt.
R
Offset+9
350
Current
Charging
Consumed
Energy(high
16 bit)
0-
65535
The high 16 bit
values of the current
charging consumed
energy.
R
Offset+A
351
Current
Charging
Consumed
Energy(low 16
bit)
0-
65535
The low 16 bit values
of the current
charging consumed
energy.
The unit of energy is
in Watt Hour.
R
Offset+B
352
Current
Charging
time---
seconds(high
16 bit)
0-
65535
The high 16 bit
values of Number of
seconds EV has been
charging
R
Offset+C
353
Current
Charging
time---
seconds(low
16 bit)
0-
65535
The low 16 bit values
of Number of
seconds EV has been
charging
R
Offset+D
354
Connected
time---
seconds(high
16 bit)
0-
65535
The high 16 bit
values of Number of
seconds EV has been
connected
R
Offset+E
355
Connected
time---
seconds(low
16 bit)
0-
65535
The low 16 bit values
of Number of
seconds EV has been
connected
R
Current Charging Information Diagnostic Registers
Table – 4.4