beautypg.com

Lamp etch, He und fq, Lamps have to have the lamp socket positioned down – OSRAM QUICKTRONIC-M ECG for circular FL 16 mm User Manual

Page 77

background image

76

7.5.3 Luminaire

Optimisation

With the mentioned measuring principle the best correlation between
ambient temperature and cold spot temperature of the T5-lamps is
achieved.

7.5.4 Maximum

luminous

flux for FH

®

…HE

fluorescent lamps

So called Horseshoe Curve shows the correlation in between the cold spot
temperature and the ambient temperature ta.

7.5.5 Verticalness

Operation

If luminares are operated in horizontal position the lamp stamp of the
FH

®

…HE und FQ

®

…HO fluorescent lamps have to be placed down.


Luminaires with circular FC

®

lamps have to have the lamp socket

positioned down.

Attach the thermocouples in the area of the lamp caps
within a distance of 2mm from the glass tube

x

Measuring point with the best correlation
between cold-spot temperature and
ambient temperature

Lamp etch

T5 FH28W (nearly constant power supply): Luminous flux / Voltage - Horseshoe

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

55%

60%

65%

70%

75%

80%

85%

90%

95%

100%

relative lamp voltage

re

la

tiv

e

light output

COLD SPOT temperature

50°C

45°C

40°C

35°C

30°C

25°C

15°C

90°C

85°C

80°C

75°C

70°C

65°C

60°C

55°C

5°C

10°C

0°C

20°C

ambient temperature

-5°C

75°C

25°C

35°C

45°C

5°C

-25°C

55°C