3. ECG installed in Luminaire:
Installations and Operation
Instructions
3.1 Wiring
Instructions
3.1.1 Cable
Types
Please pay attention to the voltage value U-OUT imprinted on the ECG
housing when wiring luminaires for FH
®
…HE or FQ
®
…HO fluorescent
lamps. This value indicates the possible cable type.
For voltages greater than 430V cables with the classification H07 have to
be used.
U-OUT is the maximum voltage that can occur between the lamp terminals
or the lamp terminal and the earth connector.
For all OSRAM QUICKTRONIC ECG for operation of T5/
∅ 16 mm-
fluorescent lamps FH
®
…HE and FQ
®
…HO U-OUT is less than 430V
allowing luminaires to be wired with cables H05.
Cable types are specified through the terminals in use.
3.1.2 Cable
Cross-Sections The cable cross-sections are marked on the identification plate of the
Electronic control gear.
Combi-Wiring (CW) stands for use in automatic or manual wiring. ECG in
30 mm height have the annex CW at the end of the type. ECG types
without CW are suitable for manual wiring only in this height. T5-ECG in
21 mm height don’t have this annex as they are equipped with CW
terminals only for manual or automatic wiring.
For manual wiring of the IDC a special tool is available for example from
WAGO. This tool is listed and can be ordered from WAGO under the order
number
0206-0831
.
Ancillary for manual wiring of the IDC-contact of the CW terminals