7. Appendix
7.1 Overview of Maximum
Cable Lengths
The following tables give an overview of the maximum cable lengths of
QUICKTRONIC
®
ECGs for T5
∅ 16 mm-fluorescent lamps FH
®
...HE and
FQ
®
...HO.
The sequence of fixing the wires to the terminals goes from the upper right
downwards.
7.1.1 QUICKTRONIC
®
INTELLIGENT
ECG-type Sequence PIN
21
PIN
22
PIN
23
PIN
24
PIN
25
PIN
26
PIN
27
QTi 1x14/24/21/39
21-27
2 2 1 1
QTi 1x28/54
21-27
2 2 1 1
QTi 1x35/49/80
21-27
2 2 1 1
QTi 2x14/24/21/39
21-27
2 2 2 1 1 1 1
QTi 2x28/54
21-27
2 2 2 1 1 1 1
QTi 2x35/49
21-27
7.1.2 QT-FH
MULTI...CW
-30 mm height-
ECG-type Sequence PIN
6
PIN
5
PIN
4
PIN
3
PIN
2
PIN
1
QT-FH 1x14-35 CW
6-1
2 2 1 1
QT-FH 2x14.35 CW
6-1
2 2 2 2 1 1
ECG-type Sequence PIN
1
PIN
2
PIN
3
PIN
4
QT-FH 1x14
1-4
2 2 1 1
QT-FH 1x21
1-4
2 2 1 1
ECG-type Sequenc
e
PIN
1
PIN
2
PIN
3
PIN
4
PIN
5
PIN
6
PIN
7
PIN
8
QT-FH 3x14 CW
1-6 re
1,5 1,5 1,5
1,5 1 1 1 1
3-8 li
ECG-type Sequence
PIN
1
PIN
2
PIN
3
PIN
4
PIN
5
PIN
6
PIN
7
PIN
8
PIN
9
PIN
10
QT-FH 4x14 CW
1-10
re
1,5 1,5 1,5 1,5 1,5 1,5 1 1 1 1
3-8 li
7.1.3 QT-FQ...CW
-30 mm height-
ECG-type Sequence PIN
6
PIN
5
PIN
4
PIN
3
PIN
2
PIN
1
QT-FQ 1x24 CW
6-1
1 1 2 2
QT-FQ 1x39 CW
6-1
1 1 2 2
QT-FQ 1x49 CW
6-1
1 1 2 2
QT-FQ 1x54 CW
6-1
1 1 2 2
QT-FQ 1x80 CW
6-1
1 1 2 2
QT-FQ 2x24 CW
6-1
2 2 2 2 1 1
QT-FQ 2x39 CW
6-1
2 2 2 2 1 1
QT-FQ 2x49 CW
6-1
2 2 2 2 1 1
QT-FQ 2x54 CW
6-1
2 2 2 2 1 1
7.1.4 QT-FH
MULTI…F/CW
-21 mm height-
ECG-type Seque
nce
PIN
1
PIN
2
PIN
3
PIN
4
PIN
5
PIN
6
PIN
7
QT-FH 1x14-35 F/CW
1-7
2 2 1 1
QT-FH 2x14-28 F/CW
1-7
1 1 2 2 2 2