Operation
Example of a daylight simulation
Cycle time 12h. Clock-controlled switch-on at 8 a.m.
Cycle time
Brightness
Time
50%
80%
90%
8:00
12:00
16:00
20:00
Scene 1
Scene 2
Scene 3
Scene 4
Troubleshooting
If you cannot remedy the fault, please contact the Customer Service department of the
luminaire manufacturer.
Fault
Cause
Remedy
Luminaire does not func-
tion
No mains voltage present.
Check the mains supply
fuses.
Illuminant defective.
Replace illuminant.
Control unit does not
respond to the remote
control
No mains voltage present.
Check the mains supply
fuses.
Illuminant defective.
Replace illuminant.
Remote control batteries
are too weak.
Check the display.
Replace the batteries if
necessary.
Remove control is outside
the range of the infrared
receiver.
Reduce the distance.
Wrong IR coding.
Check the IR coding.
Infrared receiver is
exposed to direct light.
Shade the receiver or
select another installation
location.
Control unit does not
respond to the external
pushbutton
No mains voltage present.
Check the mains supply
fuses.
Illuminant defective.
Replace illuminant.
Luminaire does not react
as expected to the press
of a button
Button was pressed too
long or too short.
See "Operation".
No mains voltage present.
Check the mains supply
fuses.
Sequence in the master-
slave mode is not syn-
chronous
Slaves have already been
programmed and have
their own scenes.
Perform a reset and
create the sequence
again.
Slave bridges are missing.
Insert the bridges.