Activating the operating modes, Switching on and off the luminaires, Changing the brightness manually – OSRAM OPTOTRONIC OT EASY 60 II User Manual
Page 13
13
OT EASY 60
IV 2009
Operation
Activating the operating modes
The lighting control mode is always active. The sequencer mode and daylight simula-
tion are activated via the DIP switches in the battery compartment of the remote
control.
Activated operating modes
DIP switch setting
Lighting control mode only
DIP switch 3 = OFF
DIP switch 4 = OFF
ON
Sequencer mode
(incl. lighting control mode)
DIP switch 3 = OFF
DIP switch 4 = ON
ON
Daylight simulation
(incl. lighting control mode)
DIP switch 3 = ON
DIP switch 4 = OFF
ON
Switching on and off the luminaires
2x
max
1
2
3
< 30 s
1
2
3
1
2
3
A
B
...
Via short press.
•
All LEDs: „On/Off dimming“ button.“.
•
LEDs (channels 1 to 4): “Ch1” to “Ch4” buttons.
Changing the brightness manually
2x
max
1
2
3
< 30 s
1
2
3
1
2
3
A
B
...
Via long press. Each repeated long key press causes a toggle between increased
brightness and decreased brightness.
•
All LEDs: „On/Off dimming“ button.“.
•
LEDs (channels 1 to 4): „Ch1“ to „Ch4“ buttons.
Note:
The LEDs of a group are all connected to the same output channel and therefore
have the same brightness.