Description :

Once paired, your PARANI10 uses the stored link key. By using this AT

command, you can make Bluetooth connection with a new link key. When n is

set to 1, your PARANI10 newly generates a link key during connection

process.

AT+UARTCONFIG, baudrate, parity, stopbit,handshaking

Function :

Configure the serial port of your PARANI10.

Response :

OK

Description :

By using this AT command, you can reconfigure the serial port of your

PARANI10. You can set baudrate, parity, stopbit . To make this command

result active, you should do soft-reset or turn off/on your PARANI10. The

following values are permitted for each parameter.

Baudrate = 1200, 2400, 9600, 19200, 38400, 57600 or 115200.

230400 (only for Parani10)

Parity = N (No parity), E (Even parity) or O (Odd parity).

Stopbit = 1 or 2.

Handshaking = 1 or 0

(If ‘1’, hardware handshaking will be used. If ‘0’, handshaking function of

Parani10 will be turned off)

Full AT commands set

No.

Command

Response

Comments

1)

AT

OK

2)

ATZ

OK

Drops all connections, disable Inquiry

and Page scans. Reset the Bluetooth

module.

3)

AT&F

OK

Reset to factory default state

4)

AT+BTINQ?

112233445

5,FriendlyName,Co

D

112233445

5,FriendlyName,Co

D

112233445

5,FriendlyName,Co

Inquiry nearby devices. The OK at

the end means end of inquiry.