beautypg.com

Lithium polymer rechargeable batteries, Electrical specification, Safety tests – Powersolve GMB Series User Manual

Page 5

background image

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]

Lithium Polymer

Rechargeable Batteries

Lithium Polymer Standard Product List (large capacity)

Type

Nominal
capacity

mAh

Nominal

Voltage

Thickness

(mm)

Width

(mm)

Length

(mm)

Weight

(grams)

GMB6265125

4800

3.7

6.2±0.2

65±0.5

125±2.0

100.0

GMB8545135

4900

3.7

8.5±0.2

45±0.5

135±3.0

102.0

GMB0832200

5000

3.7

8.0±0.2

32±0.5

200±1.0

102.0

GMB0848135

5000

3.7

8.0±0.2

48±1.0

135±1.0

102.0

GMB7553135

5000

3.7

7.5±0.2

53±0.5

135±1.0

102.0

GMB0932200

5400

3.7

9.0±0.2

32±0.5

200±1.0

106.0

GMB45103122

5500

3.7

4.0±0.2

103±0.5

122±1.0

110.0

GMB0853135

6000

3.7

8.0±0.2

53±0.5

135±3.0

128.0

GMB1050140

6500

3.7

10.0±0.2

50±0.5

140±1.0

135.5

GMB0890170

10000

3.7

8.0±0.2

90±0.5

170±1.0

240.0

GMB7872196

10000

3.7

7.8±0.2

72±0.6

196±1.0

240.0

GMB9560120

6800

3.7

9.5±0.2

60±0.5

120±1.0

145.0

Electrical Specification

Charge Voltage

4.2V per single cell

Nominal Voltage

3.7V per single cell (open circuit voltage 3.6 to 3.85V when shipped)

Nominal Capacity

At 0.2C discharge down to 2.75V cut off voltage

Cycle Life

≥300 Cycles, one cycle refers to one charge period and one discharge period.
Test condition Charge 0.2C to 4.2V discharge 0.2VC to 2.75V. The cycle time is when the
discharge capacity is about 75% of the rated capacity.

Impedance

Cell impedance ≤100mΩ

Charging Methods
Charging Current
Low Temperature Charging (0º-10ºC)
Standard Charging (0º-45ºC)
Fast Charging (10º- 45ºC)
Charge Time

Standard Constant Current: 0.2C, Fast Constant Current: 0.5C
Below 0.1C CC from 2.75V to 4.2V, then CV to 0.05C cut off
Standard 0.2C constant current to 4.2V, constant voltage at 4.2V to cut off current ≤0.05C
Fast Charge 0.5Cconstant current to 4.2V, constant voltage at 4.2V to cut of current ≤0.05C
Standard Charge 8 hours, Fast Charge time 2.8 hours

Standard Discharge Current (-10º-45ºC)

Max Discharge Current

Constant discharge at 0.2C to cut off voltage of 2.75V
1C

Discharge Cut Off Voltage

2.75V

Operating Temperature

Discharge -10ºC to +45ºC, Charge 0ºC to +45ºC. Cells must be stored at 3.6 to 3.9V. Over
long storage periods cells should be cycled every 90 days. The method is to do a
charge/discharge cycle with standard method, then charge to 3.6 to 3.9V

Operating Humidity

45-75% relative humidity

Long Term Storage Temperature

-5ºC to +35ºC, relative humidity 45-75%, Voltage 3.8V±0.1V

Note: All batteries above can be supplied in multiple packs to increase voltage or current. Custom sizes
can also be accommodated but these will be subject to tooling charges and minimum order quantities.
Consult sales office for details. All cells and battery packs are provided with Protective
Circuit Modules (PCM) to protect against over charging, over discharging and over current.

Safety Tests

Test

Test Conditions and Method

Results

Overcharge

After standard charging, the cell is connected for 8 hours while the constant voltage

is held at 4.5V and standard charging current flow through it

No explosion or fire

Short Circuit A charged battery is short circuited for 1 hour at 0.04Ω

No explosion or fire

Heat Shock

The cell is placed in a thermal chamber and temperature is raised to 120±2ºC at the rate of
5±2ºC min and held for 10 minutes, then cooled to room temperature at the rate of 5±2ºC min

No explosion or fire

Humidity and

heat test

A battery is placed in a box for 48 hours where the temperature is 40ºC±2ºC and the relative

humidity is 90-95%

No explosion or fire

5