4

Remote ON/OFF Control

External Output Trimming

Output Noise

The PS100 series allows the user to switch the module on and off electronically with remote on/off feature. The PS100

series are available with "positive logic" or "negative logic" (option).

Output may optionally be externally trimmed (+10%) with a fixed resistor or an external trimpot as shown.

The output noise is measured with 10

µF tantalum capacitor and 1.0µF ceramic capacitor across output.

HIGH SIGNAL HERE

DISABLE OUTPUT

ON/OFF (2)

-VIN (4)

Negative

Logic Table

External Output

Output Noise Test Circuit schematic

Logic Positive Logic

Logic Low -
Switch Closed

Logic High -
Switch Open

Module on

Module off

Module off

Module on

+SENSE (8)

-SENSE (6)

-SENSE (6)

+SENSE (8)

TRIM (7)

TRIM (7)

TRIM UP

TRIM DOWN

10K ohms

TRIMPOT

+Vout (9)

-Vout (5)

Ceramic

1.0µF

Solid Tantalum

10µF

To

Scope

Resistor

Load

Logic State

(Pin 2)

All Specifications Typical At Nominal Line, Full Load and 25°C Unless Otherwise Noted.