AC-DC Converters
MODEL
MAX OUTPUT POWER
OUPUT VOLTAGE
OUPUT CURRENT
FAN OUTPUT
STANDBY SUPPLY
NUMBER
(12 CFM AIR FLOW)
V1
(12 CFM AIRFLOW)
V2
V3
AHP200-12
212 W
12.0 VDC
16.7 A
12.0 V/1.0 A
5.0 V/0.1 A
AHP200-24
212 W
24.0 VDC
8.3 A
12.0 V/1.0 A
5.0 V/0.1 A
AHP200-48
205 W
48.0 VDC
4.0 A
12.0 V/1.0 A
5.0 V/0.1 A
MODELS AND RATINGS
MECHANICAL DETAILS
Notes:
1. All dimensions in inches (mm).
2. Units supplied with screw terminal (CN2) as standard. For faston type, add suffix ‘-F’ to the part number.
3. All 4 mounting positions should be connected to safety earth.
4. The air flow needs to be directed through the power supply within the end application.
AIR FLOW
12 CFM
5.00 (127.0)
4 X
ø
0.14 (3.5) MOUNTING HOLES
SAFETY EARTH - 4.8 mm Faston
SCREW
TYPE
6.35 mm
FASTONTYPE
(2)
4.55 (115.6)
0.22
(5.7)
CN1
CN3
1
1
5
10
6
2
CN2
+ve
-ve
CN2
N
L
2.55
(64.8)
3.00
(76.2)
1.22
(31.0)
0.06
(1.5)
0.06 (1.5)
TR4
T7
C42
C14
TR11
1
2
CN2
(See Thermal
considerations)
Pin 1
+V
Pin 2
V1 Return
Pin Connections - CN2
1 +V2
2 V2
Return
3 V2
Return
4
ROF
5 ROF
Return
6
Power Fail/DC OK
7
Current Share
8 +V3
9 -V3
10
+V2
Pin Connections - CN3
Mating Connectors:
CN1: Molex housing 09-50-3031 and crimp 2878.
CN3: Molex housing 51110-1050 and crimp 50394-8100.
THERMAL CONSIDERATIONS
Mating Connectors:
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. See
drawing above for component locations. The temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any
direct air flow).
Component
Max Continuous Temperature ºC
TR4 case
110 ºC
C14
105 ºC
C42
105 ºC
TR11 case
110 ºC
T7 coil
120 ºC
Temperature Measurements (Ambient 50 ºC)