beautypg.com

Ac-dc converters, Pin connections - cn2, Pin connections - cn3 – Powersolve AHP200 Series User Manual

Page 2: Temperature measurements (ambient 50 ºc)

background image

www.powersolve.co.uk

Powersolve Electronics Ltd. 8A, Arnhem Road, Newbury, RG14 5RU. England

Tel:01635 521858 Fax: 01635 523771 Email: [email protected]

AC-DC Converters

MODEL

MAX OUTPUT POWER

OUPUT VOLTAGE

OUPUT CURRENT

FAN OUTPUT

STANDBY SUPPLY

NUMBER

(12 CFM AIR FLOW)

V1

(12 CFM AIRFLOW)

V2

V3

AHP200-12

212 W

12.0 VDC

16.7 A

12.0 V/1.0 A

5.0 V/0.1 A

AHP200-24

212 W

24.0 VDC

8.3 A

12.0 V/1.0 A

5.0 V/0.1 A

AHP200-48

205 W

48.0 VDC

4.0 A

12.0 V/1.0 A

5.0 V/0.1 A

MODELS AND RATINGS

MECHANICAL DETAILS

Notes:
1. All dimensions in inches (mm).
2. Units supplied with screw terminal (CN2) as standard. For faston type, add suffix ‘-F’ to the part number.
3. All 4 mounting positions should be connected to safety earth.
4. The air flow needs to be directed through the power supply within the end application.

AIR FLOW

12 CFM

5.00 (127.0)

4 X

ø

0.14 (3.5) MOUNTING HOLES

SAFETY EARTH - 4.8 mm Faston

SCREW

TYPE

6.35 mm

FASTONTYPE

(2)

4.55 (115.6)

0.22
(5.7)

CN1

CN3

1

1

5

10

6

2

CN2

+ve

-ve

CN2

N

L

2.55

(64.8)

3.00

(76.2)

1.22

(31.0)

0.06
(1.5)

0.06 (1.5)

TR4

T7

C42

C14

TR11

1

2

CN2

(See Thermal

considerations)

Pin 1

+V

Pin 2

V1 Return

Pin Connections - CN2

1 +V2
2 V2

Return

3 V2

Return

4

ROF

5 ROF

Return

6

Power Fail/DC OK

7

Current Share

8 +V3
9 -V3

10

+V2

Pin Connections - CN3

Mating Connectors:
CN1: Molex housing 09-50-3031 and crimp 2878.
CN3: Molex housing 51110-1050 and crimp 50394-8100.

THERMAL CONSIDERATIONS

Mating Connectors:
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. See
drawing above for component locations. The temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any
direct air flow).

Component

Max Continuous Temperature ºC

TR4 case

110 ºC

C14

105 ºC

C42

105 ºC

TR11 case

110 ºC

T7 coil

120 ºC

Temperature Measurements (Ambient 50 ºC)