AC-DC Converter

CFM60T Series
60 Watt Open Frame
Triple Output

Features

Universal input range 90-264Vac

2” x 4” (50.8 x 101.6mm) size

Industry standard pin outs

Efficiency to 83%

Meets CISPR/FCC Class B, conducted

Continuous short circuit protection

INPUT
Input Voltage Range

90 - 264Vac

Frequency

47 - 63Hz

Inrush Current

50A max. @ 240Vac
Cold start @ 25°C

Conducted EMI

CISPR/FCC Class B

Isolation - Input/Output

4242VDC

Leakage Current

3.5mA max.

OUTPUT
Hold-up Time

8mS typ. @ 115Vac

Short Circuit Protection

Continuous

Temperature Coefficient

±0.05% / °C

Over voltage Protection

Auto recovery

ENVIRONMENTAL
Operating Temperature Range

0°C to 50°C

Storage Temperature Range

-20°C to +85°C

Cooling

Natural convection

Safety Approvals

cUL/UL 60950, TUV EN60950

GENERAL
Dimensions

101.6 x 50.8 x 32.0 mm
4.0 x 2.0 x 1.26 inches

Weight

170g

Electrical Specification

Typical at 25°C, nominal line and 75% load unless otherwise stated.

Output Voltage and Current Ratings

MODEL

OUTPUT

OUTPUT CURRENT

RIPPLE

VOLTAGE

LINE

LOAD

OUTPUT

% EFF.

VOLTAGE

Min.

Rated

Max.

(mV pk-pk)

ACCURACY

REG.

REG.

POWER max.

V1 = 5V

0A

4.0A

5.0A

50mV

±2%

±1%

±4%

CFM60T-01

V2 = 12V

0A

3.0A

3.7A

120mV

±5%

±1%

±3%

62W

83%

V3 = -12V

0A

0.5A

0.65A

120mV

±5%

±1%

±5%

V1 = 5V

0A

4.0A

5.0A

50mV

±2%

±1%

±4%

CFM60T-02

V2 = 15V

0A

2.5A

3.1A

150mV

±4%

±1%

±3%

62W

83%

V3 = -15V

0A

0.3A

0.5A

150mV

±5%

±1%

±5%

V1 = 5V

0A

4.0A

5.0A

50mV

±2%

±1%

±4%

CFM60T-03

V2 = 24V

0A

1.5A

1.8A

240mV

±3%

±1%

±3%

62W

83%

V3 = -12V

0A

0.5A

0.6A

120mV

±5%

±1%

±5%

V1 = 3.3V

0A

6.0A

7.5A

50mV

±4%

±1%

±5%

CFM60T-04

V2 = 5V

0A

3.0A

3.7A

50mV

±5%

±1%

±4%

40.8W

78%

V3 = -12V

0A

0.5A

0.65A

120mV

±5%

±2%

±5%

www.powersolve.co.uk

NOTE:
1. Voltage accuracy is measured at 60% rated load.
2. Output noise and ripple measured with 10µF tantalum & 0.1µF ceramic capacitors across output.
3. Line regulation is measured from 103Vac - 127Vac & 207Vac - 253Vac at rated load.
4. Load regulation is defined by changing Output1 load from 20-100% of rated with other loads at 60% of rated.