Powersolve CFM60T Series User Manual
Ac-dc converter, Cfm60t series 60 watt open frame triple output, Features
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]
AC-DC Converter
CFM60T Series
60 Watt Open Frame
Triple Output
Features
•
Universal input range 90-264Vac
•
2” x 4” (50.8 x 101.6mm) size
•
Industry standard pin outs
•
Efficiency to 83%
•
Meets CISPR/FCC Class B, conducted
•
Continuous short circuit protection
INPUT
Input Voltage Range
90 - 264Vac
Frequency
47 - 63Hz
Inrush Current
50A max. @ 240Vac
Cold start @ 25°C
Conducted EMI
CISPR/FCC Class B
Isolation - Input/Output
4242VDC
Leakage Current
3.5mA max.
OUTPUT
Hold-up Time
8mS typ. @ 115Vac
Short Circuit Protection
Continuous
Temperature Coefficient
±0.05% / °C
Over voltage Protection
Auto recovery
ENVIRONMENTAL
Operating Temperature Range
0°C to 50°C
Storage Temperature Range
-20°C to +85°C
Cooling
Natural convection
Safety Approvals
cUL/UL 60950, TUV EN60950
GENERAL
Dimensions
101.6 x 50.8 x 32.0 mm
4.0 x 2.0 x 1.26 inches
Weight
170g
Electrical Specification
Typical at 25°C, nominal line and 75% load unless otherwise stated.
Output Voltage and Current Ratings
MODEL
OUTPUT
OUTPUT CURRENT
RIPPLE
VOLTAGE
LINE
LOAD
OUTPUT
% EFF.
VOLTAGE
Min.
Rated
Max.
(mV pk-pk)
ACCURACY
REG.
REG.
POWER max.
V1 = 5V
0A
4.0A
5.0A
50mV
±2%
±1%
±4%
CFM60T-01
V2 = 12V
0A
3.0A
3.7A
120mV
±5%
±1%
±3%
62W
83%
V3 = -12V
0A
0.5A
0.65A
120mV
±5%
±1%
±5%
V1 = 5V
0A
4.0A
5.0A
50mV
±2%
±1%
±4%
CFM60T-02
V2 = 15V
0A
2.5A
3.1A
150mV
±4%
±1%
±3%
62W
83%
V3 = -15V
0A
0.3A
0.5A
150mV
±5%
±1%
±5%
V1 = 5V
0A
4.0A
5.0A
50mV
±2%
±1%
±4%
CFM60T-03
V2 = 24V
0A
1.5A
1.8A
240mV
±3%
±1%
±3%
62W
83%
V3 = -12V
0A
0.5A
0.6A
120mV
±5%
±1%
±5%
V1 = 3.3V
0A
6.0A
7.5A
50mV
±4%
±1%
±5%
CFM60T-04
V2 = 5V
0A
3.0A
3.7A
50mV
±5%
±1%
±4%
40.8W
78%
V3 = -12V
0A
0.5A
0.65A
120mV
±5%
±2%
±5%
www.powersolve.co.uk
NOTE:
1. Voltage accuracy is measured at 60% rated load.
2. Output noise and ripple measured with 10µF tantalum & 0.1µF ceramic capacitors across output.
3. Line regulation is measured from 103Vac - 127Vac & 207Vac - 253Vac at rated load.
4. Load regulation is defined by changing Output1 load from 20-100% of rated with other loads at 60% of rated.