Powersolve PAK1500 Series User Manual
Ac-dc converter, Features
![background image](/manuals/287278/1/background.png)
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]
AC-DC Converter
Input Voltage
90-264VAC, 47-63Hz / 127-370VDC. Below 100VAC, derate load linearly to 90% at 90VAC
Power Factor
EN61000-3-2 (0.98 @ 230VAC / 0.99 @115VAC at full load)
AC Input Current (typ.)
18A @ 115VAC / 9A @ 230VAC
Inrush Current
30A @ 115VAC / 45A @ 230VAC
Leakage Current
<2.5mA @ 240VAC
Output Voltage
See Table
Output Current
See Table
Voltage Tolerance
±1%
Voltage Adjust Range
±5.0% typical adjustment by potentiometer
Overload Protection
>105% of rated output power. Constant I Limiting, output latches off, recycle AC input to recover
Overvoltage Protection
See Table for values. Output latches off, recycle AC input to recover
Over Temperature Protection
Shuts down output, recovers automatically when temperature goes down
Auxiliary Power
+5V @ 0.5A (±3%)
Remote ON/OFF Control
External switch or NPN transistor to turn on/off
Power OK Signal
Open drain signal low when PSU turns on. Max. sink current 20mA, max. drain voltage 40V
Output Voltage Programming
Adjustment of output voltage between 30-105% of rated output (see graph)
Output Current Programming
Adjustment of output current between 40-100% of rated output (see graph)
Operating Temperature Range
-25°C to +60°C. Above 30°C, derate linearly to 70% load at 60°C
Operating Humidity
20-90% RH non-condensing
Storage Temperature Range
-40°C to +85°C
Storage Humidity
10-95% RH non-condensing
Temperature Coefficient
±0.02%/°C (0-50°C)
Vibration
Compliance to IEC 68-2-6, IEC 68-2-64
Safety Standards
UL60950-1, TUV EN60950-1 Approved
Withstand Voltage
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC
Isolation Resistance
I/P-O/P, I/P-FG, O/P-FG: 100MΩ / 500VDC
EMI Conduction & Radiation
Compliance with EN55022 (CISPR22) Class B
Harmonic Current
Compliance with EN61000-3-2, 3
EMS Immunity
Compliance with EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3
heavy industry level, criteria A
Cooling
Controlled by power rating & temperature (internal fan)
Dimensions
280(L) x 127(W) x 63.5(H) mm
Weight
3.2Kg
Electrical Specification
Notes:
1. All parameters NOT specifically mentioned are measured at 230Vac input, rated load and 25°C ambient temperature
2. Ripple and noise are measured at 20MHz bandwidth by using a 12” twisted pair wire terminated with a 0.1µF ceramic & 47µF electrolytic capacitors across the output
3. Derating is required at low input voltages. Below 100Vac, derate linearly to 90% load at 90Vac
4. When parallel connected, only one unit may operate if the total output load is less than 5% of rated load
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC Directives
PAK1500 Series
1500W Active PFC
Single Output
www.powersolve.co.uk
Features
•
Universal AC Input with active PFC
•
Programmable Output Voltage (30%-105%)
•
Programmable Output Current (40%-100%)
•
High Efficiency up to 90%
•
+5V/0.5A Auxiliary Output
•
Intelligent LED Indicators
•
1.5U profile, High Power Density
•
Forced current sharing for parallel operation
•
Power OK signal (Power good, logic low)
•
Remote ON/OFF, Remote Sense function
•
OVP, OLP, OTP, SCP, Fan Failure Protections