High density dc-dc modules, Output voltage and current ratings, External output trim remote on/off control – Powersolve PS200 Series User Manual
Page 2: Mechanical and connection details, Output noise, Pin connection
![background image](/manuals/287250/2/background.png)
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]
www.powersolve.co.uk
High Density DC-DC Modules
Output Voltage and Current Ratings
All specifications typical at nominal line, full load and 25°C unless otherwise stated.
All dimensions in inches (mm)
Tolerances
Inches
x.xx ±0.02
x.xxx ±0.010
Pin ±0.02
Millimeters x.x ±0.5
x.xx ±0.25
Pin ±0.5
External Output Trim
Remote ON/OFF Control
MODEL
INPUT
OUTPUT
OUTPUT
INPUT CURRENT
% EFF.
VOLTAGE
VOLTAGE
CURRENT
NO LOAD
FULL LOAD
PS200-48S25
36-75 VDC
2.5 VDC
40A
25mA
2.8A
74
PS200-48S33
36-75 VDC
3.3 VDC
40A
25mA
3.5A
79
PS200-48S05
36-75 VDC
5 VDC
40A
25mA
5A
83
PS200-48S12
36-75 VDC
12 VDC
17A
25mA
5A
85
PS200-48S15
36-75 VDC
15 VDC
13.3A
25mA
5A
85
PS200-48S24
36-75 VDC
24 VDC
8.33A
25mA
5A
85
PS200-48S28
36-75 VDC
28 VDC
7.14A
25mA
5A
85
PS200-48S48
36-75 VDC
48 VDC
4.2A
25mA
5A
85
NOTE: Nominal Input Voltage 48VDC
Mechanical and Connection Details
The PS200 Series allows the user to switch the module on and off electronically with the remote on/off feature.
The PS200 Series are available with “positive logic” or “negative logic” (option).
Logic State
(Pin 2)
Negative
Logic
Positive
Logic
Logic low-
Switch closed
Module on
Module off
Logic high-
Switch open
Module off
Module on
Output Noise
The output can be trimmed externally (±10%) using a fixed resistor or
a trimpot as shown.
The output noise is measured with a 10µF tantalum and a 1.0µF
ceramic capacitor across the output.
Logic Table
Pin Connection
Pin
Function
1
+Vin
2
ON/OFF
3
CASE
4
-Vin
5
-Vout
6
-Sense
7
Trim
8
+Sense
9
+Vout