Ac-dc converters, Acl acn – Powersolve CFM100 Series User Manual
Page 2
![background image](/manuals/287249/2/background.png)
Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: [email protected]
www.powersolve.co.uk
AC-DC Converters
Note:
1. CFM100S05/090/120: Add a 0.1
µF ceramic capacitor and a 220 µF E.L. capacitor to output for ripple & noise measuring @ 20MHz
BW. Other Models: Add a 0.1
µF ceramic capacitor and a 10 µF E.L capacitor for ripple & noise measuring @ 20MHz BW.
2. Line Regulation is Measured from High Line to Low Line with Full Load.
3. Load Regulation is Measured from Full to 10% Load.
4. Dimensions tolerance: + 1mm
5. Connectors: AC input : Molex 5277 or equivalent
DC output : Molex 5273 or equivalent
6. DC output pin 1, 2, 3, 4: Vout (+)
DC output pin 5, 6, 7. 8 : Vout (-)
33
.6
30
64
.8
5.7
76
.2
1.6
2
127
115.6
ACL
ACN
5.7
1
2
3
4
5
6
7
8
MODEL
OUTPUT MAX MIN RIPPLE
& VOLTAGE
LINE
LOAD
VOLTAGE
LOAD
LOAD
NOISE
ACCURACY REGULATION
REGULATION
CFM100S050
5V
20 A
0A
1%
±1%
±0.5%
±1%
CFM100S090
9V
11.2 A
0A
1%
±1%
±0.5%
±1%
CFM100S120
12V
8.4 A
0A
1%
±1%
±0.5%
±1%
CFM100S150
15V
6.7 A
0A
1%
±1%
±0.5%
±1%
CFM100S180
18V
5.6 A
0A
1%
±1%
±0.5%
±1%
CFM100S240
24V
4.2 A
0A
1%
±1%
±0.5%
±1%
CFM100S480
48V
2.1 A
0A
1%
±1%
±0.5%
±1%