Powersolve CFM200S Series User Manual
Ac-dc converter, Features
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]
AC-DC Converter
CFM 200S Series
200 Watt U-Frame
Single Output
Input Voltage Range
90 - 264Vac
Frequency
47 - 63Hz
Inrush Current
60A max. @ 264Vac
Conducted EMI
CISPR/FCC Class B
Isolation - Input/Output
4242VDC
Leakage Current
3.5mA max.
Total Rated Output Power
200W (with 30CFM air flow or optional fan)
Current Share (parallel operation)
Single wire current sharing (connection pin 7 of CN6)
Remote Voltage Sense
Compensates for wire voltage drop
Hold-up Time
16mS typ. @ 115Vac
Over Voltage Protection
Recycle AC input to restart
Over Temperature Protection
Auto-recovery
Short Circuit Protection
Auto-recovery
Operating Temperature Range
0°C to +70°C (Derate at 2.5% / °C over 50°C)
Storage Temperature Range
-20°C to +85°C
Safety Approvals
cUL/UL 60950, TUV EN60950
Dimensions
150 x 100 x 38.1 mm (Standard U-Frame)
(5.91 x 3.94 x 1.5 inches)
150 x 101.6 x 58.5 mm (With optional top cover & fan fitted)
(5.91 x 4 x 2.3 inches)
Weight
700g (800g with top cover & fan fitted)
Electrical Specification
www.powersolve.co.uk
Features
•
Universal input range 90-264Vac
•
Active PFC meets EN61000-3-2
•
Efficiency to 80%
•
Meets CISPR/FCC Class B
•
Current Sharing & Remote On/Off Control
•
Overvoltage, Over Temperature & Short Circuit protection
Output Voltage and Current Ratings
MODEL
OUTPUT
OUTPUT CURRENT
RIPPLE
VOLTAGE
LINE
LOAD
VOLTAGE
Min.
Max.
(mV pk-pk)
ACCURACY
REG.
REG.
CFM200S-033
3.3V
0A
40.0A
1%
±1%
±1%
±1%
CFM200S-050
5.0V
0A
40.0A
1%
±1%
±1%
±1%
CFM200S-090
9.0V
0A
22.2A
1%
±1%
±1%
±1%
CFM200S-120
12V
0A
16.7A
1%
±1%
±1%
±1%
CFM200S-150
15V
0A
13.4A
1%
±1%
±1%
±1%
CFM200S-180
18V
0A
11.2A
1%
±1%
±1%
±1%
CFM200S-240
24V
0A
8.4A
1%
±1%
±1%
±1%
CFM200S-280
28V
0A
7.2A
1%
±1%
±1%
±1%
CFM200S-300
30V
0A
6.7A
1%
±1%
±1%
±1%
CFM200S-360
36V
0A
5.6A
1%
±1%
±1%
±1%
CFM200S-480
48V
0A
4.2A
1%
±1%
±1%
±1%
Suffix 001: without top fan & cover. Suffix 002: with top fan & cover.
NOTE:
1. Output noise and ripple measured with 47µF electrolytic & 0.1µF ceramic capacitors across output.
2. Voltage accuracy is set at 60% rated load & 25°C ambient temperature.
3. Line regulation is measured from High Line to Low Line at rated load.
4. Load regulation is measured from 20% -100% of full load.