beautypg.com

Ac-dc converters – Powersolve CFM20 Series User Manual

Page 2

background image

Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England

Tel:01635 521858 Fax: 01635 523771 Email: [email protected]

www.powersolve.co.uk

AC-DC Converters

Note:
1. Add a 0.1F ceramic capacitor and a 10F E.L. capacitor to output for Ripple & Noise Measuring @ 20MHz BW.

2. Line Regulation is Measured from High Line to Low Line with Full Load.

3. Load Regulation is Measured from Full to 10% Load.

4. Input Connector Mates with Molex Housing 09-50-3031 and Molex 2878 Series Crimp Terminal.

5. Output Connector Mates with Molex Housing 09-50-3041 and Molex 2878 Series Crimp Terminal.

6. Model "CFM200XS-P": Connectors with PCB Mountable Type.

1.0(25.4)

0.15(3.8)

0.23(6.05) 0.13(3.30)(4PL)

0.31(7.9)

2.00(50.8)

1.70(43.18)

0.150(3.81)

0.150(3.81)

3.2(81.28)

3.50(88.9)

0.070(1.78)

0.040(1.02)

0.24(6.12)

0.62(15.75)

0.15(3.96)

ACN

ACL

+Vout

-Vout

VR

0.80(20.32

)

2.00(50.8)

1.70(43.18)

0.150(3.81

)

0.150(3.81)

3.2(81.28)

3.50(88.9)

0.13(3.30)(4PL)

ACN

ACL

-Vout

+Vout

VR

CFM20 Watt Series

CFM200XS-P Watt Series

MODEL

OUTPUT MAX MIN RIPPLE

& VOLTAGE

LINE

LOAD

EFF

VOLTAGE

LOAD

LOAD

NOISE

ACCURACY REGULATION

REGULATION

%

CFM2001S

5V

4400mA

0A

1%

±1%

±0.5%

±1%

73

CFM2002S

12V

1800mA

0A

1%

±1%

±0.5%

±1%

80

CFM2003S

15V

1400mA

0A

1%

±1%

±0.5%

±1%

80

CFM2005S

24V

920mA

0A

1%

±1%

±0.5%

±1%

82

CFM2007S

3.3V

4400mA

0A

50mV

±1%

±0.5%

±1%

70

CFM2009S

9V

2450mA

0A

1%

±1%

±0.5%

±1%

77