beautypg.com

Powersolve Slave Series Adapter User Manual

Master / slave - series adapter, Features, General

background image

MASTER

/

SLAVE

- SERIES ADAPTER

Features

• Programming and monitor offset

: +/- 60 µV typical

• Full scale error

: 0.1 % calibrated

• Non-linearity

: 0.01% typical, 0.05 % max. TC = 65 ppm/°C

• Common mode rejection

: 80 dB @ 50 Hz

• Temperature coefficient

: -65 ppm typical

• Voltage range

: 0 - 5 V

• Offset

: ±60 µV typical, ± 180 mV max.

The full scale voltage of the M / S
SERIES ADAPTER is
factory-calibrated within 0.1 %.

Offset, full scale error, non-linearity
and temperature coefficient have to be
added to the specifications of the
power supply.

General

• A 15 pole 1:1 cable (0.6m) is supplied with the ADAPTER.
• The number of M / S SERIES ADAPTERS needed is one less than the number of

power supplies in the series system (see example).

• For remote programming and monitoring please refer to the power supplies’ manual.

Example with 3 power supplies

Specifications

Unit 8A
Arnhem Road
Newbury. RG14 5RU

Tel: +44 (0) 1635 521858
Fax: +44 (0) 1635 523771
www.powersolve.co.uk

• Connecting SM-3000 and ES-Series in master/slave series mode
• The master power supply can be upper or the lower power supply in the series
• Easy way of connection power supplies in the master /slave series mode
• Equal voltage sharing in the series operation
• Series operation possible up to 600 V