beautypg.com

Powersolve TEX Series User Manual

Ac-dc converters, Tex series, 120 watt, Features

background image

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England

Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]

AC-DC Converters

TEX Series, 120 Watt

Electrical Specification

Input voltage range

90-264Vac, 47-63Hz / 85-375VDC (Option: DC input 18-75VDC)

EMI suppression

EN55011/22 class B, harmonic current EN 61000-3-2 class A

EMC immunity

EN61000-6-2, SEMI F47

Output current limitation

>125% of Inom.

Operating Temperature Range

-40°C to +85°C (convection cooling) (derate at 2.0%/°C above 60°C)

Safety Approvals

UL 508 listed (pending),IEC/ EN 60950-1, CB report, EN 51078, EN 60204, EN61558-2-8,
IEC/EN 60079-15 (class I, Div. 2), UL 60079-15, ANSI/ISA 12.12.01 (class I Div.2), EN 50021,
ATEX 94/9/EC

Degree of protection

safety class I, (IEC 536)

Casing protection

IP66/67 (IEC529) complies to NEMA 4X standard

Shock & vibration

meets IEC 60068-2-6, IEC 60068-2-27

Humidity

to 98% without compensation

Output Voltage and Current Ratings

MODEL

OUTPUT

OUTPUT VOLTAGE

OUTPUT

RIPPLE &

LINE

LOAD

EFF.

POWER

SET POINT

Adj. RANGE

CURRENT max.

NOISE

REG.

REG.

TEX 120-112

120W

12VDC

12 - 15VDC

8A

50mV pk-pk max.

0.5%

1.0%

90%

TEX 120-124

120W

24VDC

24 - 28VDC

5A

50mV pk-pk max.

0.5%

1.0%

90%

Mechanical Details

Mating connectors (not supplied)
AC Input: Binder 3 pin female circular plug 99-4222-14-04
DC Output: Binder 7 pin male circular plug 99-4225-160-07
units are supplied with sealing connector caps

Features

Sealed, rugged die-cast aluminium casing

Dust & water resistant to IP67 & NEMA 4X

Wide operating temperature range -40°C to +85°C

Easy connection via waterproof plugs

Universal input 90-264Vac (optional DC input of 18-75VDC)

Adjustable output voltage, short circuit and overload protection

UL 508 listed

ATEX & ANSI approval for hazardous locations (Class I, Div. 2)

www.powersolve.co.uk

Input Connector

Pin

Function

1

AC(L)

2

AC(N)
Earth

Output Connector

Pin

Function

1

-Vout

2

-Vout

3

-Vout

4

+Vout

5

+Vout

6

+Vout

7

Case

Dimensions in mm (inch)
Tolerances: ±0.5 (±0.02)