20-36 Watt Switch Mode
Universal AC Input

INPUT
Input Voltage Range

90 - 264Vac

Frequency

50 - 60Hz

Inrush Current

60A max. @ 240Vac

Conducted EMI

CISPR/FCC Class B

Isolation - Input/Output

4242VDC

Leakage Current

0.25mA max.

OUTPUT
Hold-up Time

8mS typ. @ 115Vac

Short Circuit Protection

Continuous

Over Voltage Protection

Yes

ENVIRONMENTAL
Operating Temperature Range

0°C to +40°C

Storage Temperature Range

-20°C to +85°C

Cooling

Natural convection

GENERAL
Safety Approvals

cUL/UL 60950, TUV EN60950

Dimensions

110.0 x 50.0 x 20.0 mm
4.331 x 1.969 x 0.787 inches

Weight

190g

AC Inlet

IEC320/C8

Electrical Specification

Features

Universal Input Range 90-264Vac

Continuous Short Circuit Protection

Over Voltage Protection

Conductive EMI Meets CISPR/FCC Class B

CEC Level IV Compliant (Output cable length ≤1800mm)

(PS36E090: Output cable ≤1220mm)
(PS36E050: Output cable ≤1220mm, 18AWG/UL2464)

Optional Output Connectors

www.powersolve.co.uk

Output Voltage and Current Ratings

MODEL

OUTPUT

OUTPUT

RIPPLE &

VOLTAGE

LINE

LOAD

% EFF.

VOLTAGE

CURRENT

NOISE

SETPOINT

REG.

REG.

PS36E050

5V

4.0A

1%

±2%

±1%

±6%

73%

PS36E090

9V

3.0A

1%

±2%

±1%

±5%

77%

PS36E120

12V

2.5A

1%

±2%

±1%

±5%

78%

PS36E130

13.5V

2.4A

1%

±2%

±1%

±5%

80%

PS36E150

15V

2.4A

1%

±2%

±1%

±3%

80%

PS36E180

18V

2.0A

1%

±2%

±1%

±2%

81%

PS36E240

24V

1.5A

1%

±2%

±1%

±2%

81%

PS36E480

48V

0.75A

1%

±2%

±1%

±2%

83%

NOTE:
1. Voltage set point at 60% full load.
2. Output noise and ripple measured with 10µF electrolytic & 0.1µF ceramic capacitors across output at 20MHz BW.
3. Line regulation is measured from 100Vac to 240Vac at full load.
4. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% load).