Ac-dc converters – Powersolve JB400 Series User Manual
Page 2

Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: [email protected]
www.powersolve.co.uk
AC-DC Converters
Model
Output Range
(Factory Set)
Preset
Voltage
Max Output Power or Current
Convection Forced Air
Total Regulation
Ripple & Noise
Min Efficiency
@ full load
JB400X-03(I)(M)
2-3.3V DC
3.3V DC
45A 60A
±1%
±1%
70%
JB400X-05(I)(M)
5-6V DC
5V DC
45A 60A
±1%
±1%
75%
JB400X-12(I)(M)
12-15V DC
12V DC
250W 400W
±1%
±1%
80%
JB400X-18(I)(M)
16-21V DC
18V DC
250W 400W
±1%
±1%
83%
JB400X-24(I)(M)
22-30V DC
24V DC
250W 400W
±1%
±1%
83%
JB400X-36(I)(M)
31-41V DC
36V DC
250W 400W
±1%
±1%
83%
JB400X-48(I)(M)
42-58V DC
48V DC
250W 400W
±1%
±1%
83%
Output Voltage & Current Ratings (Single Output)
Output Voltage & Current Ratings (Dual Outputs)
Model
DC Outputs
Max Output Current
Convection Forced Air
Total Regulation
Ripple & Noise
Min Efficiency
@ full load
JB400DX-0312(M)
V1: +3.3V
V2: +12V
30A 40A
16.7A 25A
±5%
±5%
±1%
±1%
75%
JB400DX-0324(M)
V1: +3.3V
V2: +24V
30A 40A
8.34A 12.5A
±5%
±5%
±1%
±1%
75%
JB400DX-0512(M)
V1: +5V
V2: +12V
30A 40A
16.7A 25A
±5%
±5%
±1%
±1%
75%
JB400DX-0524(M)
V1: +5V
V2: +24V
30A 40A
8.34A 12.5A
±5%
±5%
±1%
±1%
75%
JB400DX-1224(M)
V1: +12V
V2: +24V
16.7A 25A
8.33A 12.5A
±5%
±5%
±1%
±1%
75%
Note:
X in model number above = U for U channel version or E for enclosed with end fan, if top cover required on U channel version add suffix -
CVR to end of part number. E enclosed version is available with either screw terminal AC input or IEC320-14 inlet connector with
ON/OFF switch. Add suffix -ST to end of part number for screw terminals or -IEC for IEC inlet. U channel version is also available with
either Molex input and output connectors or screw terminals. Add suffix - MX to end of part number for Molex or -ST for screw terminals.
Options:
(I) in part number is for single wire current sharing and includes or’ing diodes
(M) in part number above is for medical safety approvals and low earth leakage current
For AC Power fail add suffix -ACP to part number above.
For example a 12V medically approved enclosed fan cooled unit with IEC inlet, Current Sharing and AC Power Fail would be as follows:-
JB400E-12IM-IEC-ACP
Regulation & Ripple & Noise:
Figures above are with 1% minimum load, however unit is able to operate from zero load but there may be a slight difference in specified
limits above.
Note:
Maximum combined power of VI & V2 above is 250W convection cooled (U Channel version) or 400W with 23 CFM forced air cooling.
X in model number above = U for U Channel Version or E for enclosed with end fan, if top cover required on U channel version add suffix
-CVR to end of part number. E enclosed version is available with either screw terminal AC input or IEC320-14 inlet connector with
ON/OFF switch. Add suffix -ST to end of part number for screw terminals or -IEC for IEC inlet. U channel version is also available with
either Molex input and output connectors or screw terminals. Add suffix - MX to end of part number for Molex or -ST for screw terminals.
Regulation & Ripple & Noise:
Figures above are with 10% minimum load on both outputs to maintain regulation.