AC-DC Converters
Note:
1. Add a 0.1
µF ceramic capacitor and a 10µF E.L. capacitor to output for Ripple & Noise measuring @20MHz BW.
2. Line regulation is measured from High Line to Low Line with full load.
3. Load regulation is measured from Full to 10% load.
4. Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal.
5. Output connector mates with Molex housing 09-50-3041 and Molex 2878 series crimp terminal.
3.70 (94.00)
0.150 (3.80)
4.00 (101.60)
1.20 (30.48)
0.150 (3.80)
1.70 (43.20)
2.00 (50.80)
ACL
ACN
Vout (-)
VR
Vout (+)
LED
MODEL
OUTPUT MAX MIN RIPPLE
& VOLTAGE
LINE
LOAD
EFF
VOLTAGE
LOAD
LOAD
NOISE
ACCURACY REGULATION
REGULATION
%
CFM40S033
3.3V
6A
0A
50mV
±1%
±0.5%
±1%
74
CFM40S050
5V
6A
0A
1%
±1%
±0.5%
±1%
78
CFM40S090
9V
4.45A
0A
1%
±1%
±0.5%
±1%
82
CFM40S120
12V
3.34A
0A
1%
±1%
±0.5%
±1%
84
CFM40S150
15V
2.67A
0A
1%
±1%
±0.5%
±1%
85
CFM40S240
24V
1.67A
0A
1%
±1%
±0.5%
±1%
86
CFM40S300
30V
1.33A
0A
1%
±1%
±0.5%
±1%
86
CFM40S360
36V
1.11A
0A
1%
±1%
±0.5%
±1%
87
CFM40S480
48V
0.834A
0A
1%
±1%
±0.5%
±1%
88
40 Watt Series
MODEL
OUTPUT MAX MIN RIPPLE
& VOLTAGE
LINE
LOAD
EFF
VOLTAGE
LOAD
LOAD
NOISE
ACCURACY REGULATION
REGULATION
%
CFM60S033
3.3V
8A
0A
50mV
±1%
±0.5%
±1%
74
CFM60S050
5V
8A
0A
1%
±1%
±0.5%
±1%
78
CFM60S090
9V
6.67A
0A
1%
±1%
±0.5%
±1%
82
CFM60S120
12V
5A
0A
1%
±1%
±0.5%
±1%
84
CFM60S150
15V
4A
0A
1%
±1%
±0.5%
±1%
85
CFM60S240
24V
2.5A
0A
1%
±1%
±0.5%
±1%
86
CFM60S300
30V
2A
0A
1%
±1%
±0.5%
±1%
86
CFM60S360
36V
1.67A
0A
1%
±1%
±0.5%
±1%
87
CFM60S480
48V
1.25A
0A
1%
±1%
±0.5%
±1%
88
60 Watt Series