11
Last Gasp Alarm
The iMediaChassis series includes the Last Gasp trap feature, “Remote Chassis
Down”, which sends a Trap when the following occurs:
• Both power supply modules malfunction
• Both power supply modules are powered down
• When the AC line fails
Temperature Gauge
The iMediaChassis/6 includes a temperature monitoring gauge with a heat sensor on
the backplane of the chassis. Users define a threshold for chassis temperature via
SNMP. If the chassis’ temperature rises above the specified level, the SNMP agent
sends a trap (configured in iView²) to the administrator. There is also an LED
indicator on the SNMP Management Module for chassis temperature.
SNMP Write Lock
There is an SNMP Write Lock switch located above the SNMP module slot on the
front of the iMediaChassis/6. The SNMP Write Lock switch prevents a new
management board from re-configuring the
application module settings (e.g., the status of
features such as LinkLoss, FiberAlert, Force mode,
etc.) made via SNMP on any previous Management
Modules.
NOTE
Leave this switch in the NORMAL position during day-to-day operation; the
LOCKED position should only be used when changing the SNMP management
board.
The SNMP Management Module can be removed and replaced as necessary. Refer
to the SNMP Management Module manual for complete instructions about
configuration and operation. If an SNMP Management Module is installed, refer to
the LED panel below for indicators of Link, Temperature, Power Supply modules and
other functions.